Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Miniature Circuit Breaker
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
60mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
Class I, LPL I,II,III,IV with remote alert
Class I, LPL I,II,III,IV without remote alert
Class I, LPL III,IV with remote alert
Class I, LPL III,IV without remote alert
LPL I,II,III,IV N-PE sparkover gap 260 V / 440 V
VPU I spare arrester
L-PEN 280 V
L-PEN 400 V
N-PE 260 V
N-PE 440 V
General ordering data
Version
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Order No.
2067650000
Type
VPU I 0 280V/25KA
GTIN (EAN)
4050118416220
Qty.
1 pc(s).
Dimensions and weights
Depth
64 mm
Depth (inches)
2.52 inch
Height
52 mm
Height (inches)
2.047 inch
Width
35.6 mm
Width (inches)
1.402 inch
Net weight
85 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
1
Protection degree
IP20
Colour
orange
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
IV
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Leakage current at Un
100 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Max. continuous voltage, Uc (AC)
280 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.4 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 100 ns
Short-circuit current rating ISCCR
25 kA
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
438 V
Voltage type
AC
Electrical data
Voltage type
AC
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Type of connection:
pluggable
Order No.:
1352120000
Type:
VPU I 0 280V/12,5KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Type of connection:
pluggable
Order No.:
1352000000
Type:
VPU I 0 LCF 280V/12,5KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Type of connection:
pluggable
Order No.:
1351540000
Type:
VPU I 0 LCF 280V/25KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Version
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Order No.
2067650000
Type
VPU I 0 280V/25KA
GTIN (EAN)
4050118416220
Qty.
1 pc(s).
Depth
64 mm
Depth (inches)
2.52 inch
Height
52 mm
Height (inches)
2.047 inch
Width
35.6 mm
Width (inches)
1.402 inch
Net weight
85 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
1
Protection degree
IP20
Colour
orange
Pollution severity
2
Surge voltage category
IV
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Leakage current at Un
100 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Max. continuous voltage, Uc (AC)
280 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.4 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 100 ns
Short-circuit current rating ISCCR
25 kA
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
438 V
Voltage type
AC
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Type of connection:
pluggable
Order No.:
1352120000
Type:
VPU I 0 280V/12,5KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Type of connection:
pluggable
Order No.:
1352000000
Type:
VPU I 0 LCF 280V/12,5KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
Type of connection:
pluggable
Order No.:
1351540000
Type:
VPU I 0 LCF 280V/25KA
Version:
Surge voltage arrester, Low voltage, Accessories, Spare arrester
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.