Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
Class I, LPL I,II,III,IV with remote alert
Class I, LPL I,II,III,IV without remote alert
Class I, LPL III,IV with remote alert
Class I, LPL III,IV without remote alert
LPL I,II,III,IV N-PE sparkover gap 260 V / 440 V
VPU I spare arrester
VPU I 280 V 25 kA
VPU I 400 V 25 kA
General ordering data
Version
Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase, TN, IT with N, IT without N, TT
Order No.
2063060000
Type
VPU I 1+1 280V/25KA
GTIN (EAN)
4050118414721
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-03-31
Alternative product
2726680000
Dimensions and weights
Depth
69 mm
Depth (inches)
2.717 inch
Height
94 mm
Height (inches)
3.701 inch
Width
71.2 mm
Width (inches)
2.803 inch
Mounting dimension - height
75 mm
Net weight
580 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
1
Protection degree
IP20
Colour
black, orange, blue
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
IV
Rated data IEC / EN
Discharge current Imax (8/20µs) N-PE
100 kA
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) N-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Fuse
No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Leakage current at Un
100 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Lightning test current, Iimp (10/350 µs) (N-PE)
100 kA
Low voltage network
Single-phase, TN, IT with N, IT without N, TT
Mains voltage
240 V
Max. continuous voltage, Uc (AC)
280 V
Max. continuous voltage, Uc (N-PE)
260 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.4 kV
Protection level Up at IN (N-PE)
≤ 1.6 kV
Rated load current IL
100 A
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
No
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
438 V
Voltage type
AC
Connection data
Stripping length
15 mm
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
50 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
50 mm²
Electrical data
Voltage type
AC
Important note
Product information
Only applicable to IT power systems where the earth on the distribution transformer is interconnected with the earth on the consumer side (RE=RA in Figure 44.A1 of IEC 60634-4-44:2018).
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
User Documentation
Catalogues
Catalogues in PDF-format
Brochures
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Version
Surge voltage arrester, Low voltage, without telecomm. contact, Single-phase, TN, IT with N, IT without N, TT
Order No.
2063060000
Type
VPU I 1+1 280V/25KA
GTIN (EAN)
4050118414721
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-03-31
Alternative product
2726680000
Depth
69 mm
Depth (inches)
2.717 inch
Height
94 mm
Height (inches)
3.701 inch
Width
71.2 mm
Width (inches)
2.803 inch
Mounting dimension - height
75 mm
Net weight
580 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
1
Protection degree
IP20
Colour
black, orange, blue
Pollution severity
2
Surge voltage category
IV
Discharge current Imax (8/20µs) N-PE
100 kA
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) N-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Fuse
No Fuse neccessary ≤250 A gG, 250 A gL (if back up fuse > 250 A)
Leakage current at Un
100 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Lightning test current, Iimp (10/350 µs) (N-PE)
100 kA
Low voltage network
Single-phase, TN, IT with N, IT without N, TT
Mains voltage
240 V
Max. continuous voltage, Uc (AC)
280 V
Max. continuous voltage, Uc (N-PE)
260 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.4 kV
Protection level Up at IN (N-PE)
≤ 1.6 kV
Rated load current IL
100 A
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
No
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
438 V
Voltage type
AC
Stripping length
15 mm
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
50 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
50 mm²
Product information
Only applicable to IT power systems where the earth on the distribution transformer is interconnected with the earth on the consumer side (RE=RA in Figure 44.A1 of IEC 60634-4-44:2018).
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.