Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
General ordering data
Version
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.
2044840000
Type
ACT20C-CML-10-AO-RC-S
GTIN (EAN)
4050118409826
Qty.
1 pc(s).
Dimensions and weights
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
17.5 mm
Width (inches)
0.689 inch
Net weight
134 g
Temperatures
Storage temperature
-40 °C...85 °C
Humidity
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
130 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Communication
Configuration
for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software, DIP switch and potentiometer
Input
Input frequency
AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Input measurement range
configurable, 0…1/5/10 A AC (RMS) or DC
Input signal
Power cable can be connected to the terminals
Output
Load impedance current
≤ 600 Ω
Output (digital)
Max. switching voltage, AC
250 V
Max. switching voltage, DC
24 V
Rated switching current
2 A
Type
Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s
Output (analogue)
Load resistance current
≤ 600 Ω
Load resistance voltage
≥ 10 kΩ
Output current
Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage
Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output)
Voltage and current output (configurable)
alarm output
Switching current
5 A
General data
Accuracy
≤ ±0.3 % @ 1 A / 5 A, ≤ ±0.6 % @ 10 A
Configuration
for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software, DIP switch and potentiometer
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.
2.2 W
Protection degree
IP20
Rail
TS 35
Step response time
≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient
≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply
24 V DC ± 30 %
Insulation coordination
EMC standards
IEC 61326-1
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage
6 kV (1.2/50 µs)
Pollution severity
2
Rated voltage
300 V ACrms
Surge voltage category
III
Test voltage
4 kV
Connection data
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
3.5 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002475
ETIM 7.0
EC002475
ETIM 8.0
EC002475
ETIM 9.0
EC002475
ECLASS 9.0
27-21-01-23
ECLASS 9.1
27-21-01-23
ECLASS 10.0
27-21-01-23
ECLASS 11.0
27-21-01-23
ECLASS 12.0
27-21-01-23
ECLASS 13.0
27-21-01-23
ECLASS 14.0
27-21-01-23
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Colour:
black
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
Type of connection:
RJ45 plug-in connector
Order No.:
1510370000
Type:
ACT20C-GTW-100-MTCP-S
Version:
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus, Input : 0…40/50/60 A, Output : Pulse
Type of connection:
Screw connection
Order No.:
1510240000
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510420000
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
socket / socket
Order No.:
1510340000
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
Version
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.
2044840000
Type
ACT20C-CML-10-AO-RC-S
GTIN (EAN)
4050118409826
Qty.
1 pc(s).
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
17.5 mm
Width (inches)
0.689 inch
Net weight
134 g
Storage temperature
-40 °C...85 °C
Humidity
5...95 %, no condensation
SIL in compliance with IEC 61508
None
MTTF
130 a
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Configuration
for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software, DIP switch and potentiometer
Input frequency
AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic average)
Input measurement range
configurable, 0…1/5/10 A AC (RMS) or DC
Input signal
Power cable can be connected to the terminals
Load impedance current
≤ 600 Ω
Max. switching voltage, AC
250 V
Max. switching voltage, DC
24 V
Rated switching current
2 A
Type
Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm delay (configurable) 0…180 s
Load resistance current
≤ 600 Ω
Load resistance voltage
≥ 10 kΩ
Output current
Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Output voltage
Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Type (analogue output)
Voltage and current output (configurable)
Accuracy
≤ ±0.3 % @ 1 A / 5 A, ≤ ±0.6 % @ 10 A
Configuration
for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis, via gateway (ACT20C-GTW-100-MTCP-S), With FDT/DTM software, DIP switch and potentiometer
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Power consumption, max.
2.2 W
Protection degree
IP20
Rail
TS 35
Step response time
≤ 300 ms (RMS), ≤ 60 ms (AA)
Temperature coefficient
≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
Voltage supply
24 V DC ± 30 %
EMC standards
IEC 61326-1
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
Impulse withstand voltage
6 kV (1.2/50 µs)
Pollution severity
2
Rated voltage
300 V ACrms
Surge voltage category
III
Test voltage
4 kV
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
3.5 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
ETIM 6.0
EC002475
ETIM 7.0
EC002475
ETIM 8.0
EC002475
ETIM 9.0
EC002475
ECLASS 9.0
27-21-01-23
ECLASS 9.1
27-21-01-23
ECLASS 10.0
27-21-01-23
ECLASS 11.0
27-21-01-23
ECLASS 12.0
27-21-01-23
ECLASS 13.0
27-21-01-23
ECLASS 14.0
27-21-01-23
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Colour:
black
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
Type of connection:
RJ45 plug-in connector
Order No.:
1510370000
Type:
ACT20C-GTW-100-MTCP-S
Version:
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus, Input : 0…40/50/60 A, Output : Pulse
Type of connection:
Screw connection
Order No.:
1510240000
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510420000
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
socket / socket
Order No.:
1510340000
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.