Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Controls
I/O Systems
Industrial Ethernet
Touch Panels
Engineering and Visualisation Tools
Measuring and Monitoring Systems
Automated Machine Learning
easyConnect
I/O System IP20 - u-remote
I/O System IP67 - u-remote
Field bus coupler
Modules
Accessories
Digital input modules
Digital output modules
Digital input and output modules
Pulse width modulation and stepper motor modules
Analogue input modules
Temperature modules and potentiometer input module
Strain gauge module
Power measurement module
Analogue output modules
Digital counter- and communication- modules
Safe I/O modules and safe power-feed modules
Power-feed modules
Potential distribution modules
Replacement parts
General ordering data
Version
Remote I/O module, IP20, 6-channel, Input, Power measurement, PUSH IN connection
Order No.
2007420000
Type
UR20-3EM-230V-AC
GTIN (EAN)
4050118392777
Qty.
1 pc(s).
Dimensions and weights
Depth
76 mm
Depth (inches)
2.992 inch
Height
120 mm
Height (inches)
4.724 inch
Width
11.5
Width (inches)
0.453 inch
Mounting dimension - height
128 mm
Net weight
90 g
Temperatures
Storage temperature
-40 °C ... +85 °C
Operating temperature
-20 °C ... +60 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
82327f13-cd27-455a-ab5b-a62e1996dcf8
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
analogue inputs
Analysis of harmonic
31 (Blackmann-Harris Window)
Category for voltage measurements
CAT II (IEC 61010 Part 1)
Connectable converter ratios
1 … 1000
Frequency of the supply system
45…65 Hz
Input impedance voltage
2.4 MΩ per channel
Insulation
1.5 kVeff. (input / system)
Measurement accuracy
0.5% in relation to final value (U / I), 1% for the calculated values
Measurement method
High Resolution Delta Sigma (current measurement in outer conductor)
Measurement resistance (shunt)
4 mΩ (at 5 A), 20 mΩ (at 1 A)
Module diagnosis
Yes
Nominal peak voltage
4 kV
Number
3
Power rating
0…1 A / 0…5 A AC
Rated voltage
300 Veff (L-N), 520 Veff (L-L)
Resolution
16 bit per channel (internal 24 bit)
Sampling rate of current measurement
3,300 samples/s
Connection data
Number
3
Type of connection
PUSH IN
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire connection cross section, finely stranded, min.
0.14 mm²
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, max. (AWG)
AWG 16
Wire cross-section, solid, min.
0.14 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
General data
Air humidity (operation)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport)
10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation)
≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity
2
Rail
TS 35
Shock
15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category
II
Test voltage
500 V
UL 94 flammability rating
V-0
Vibration resistance
5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Power supply
Current consumption from IIN (the respective power segment)
12 mA
Current consumption from Isys , typ.
8 mA
Voltage supply
24 V DC +20 %/ -15 %, via the system bus
System data
Configuration interface
Micro USB 2.0
Field bus protocol
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
Galvanic isolation
500 V DC between the current paths
Interface
u-remote system bus
Module type
Functional module
Process data
32 Byte
Transmission speed of system bus, max.
48 Mbit
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Product Change Notification
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC001601
ETIM 7.0
EC001601
ETIM 8.0
EC001601
ETIM 9.0
EC001601
ECLASS 9.0
27-24-26-05
ECLASS 9.1
27-24-26-05
ECLASS 10.0
27-24-26-05
ECLASS 11.0
27-24-26-05
ECLASS 12.0
27-24-26-05
ECLASS 13.0
27-24-26-05
ECLASS 14.0
27-24-26-05
There are no products in this group.
Version
Remote I/O module, IP20, 6-channel, Input, Power measurement, PUSH IN connection
Order No.
2007420000
Type
UR20-3EM-230V-AC
GTIN (EAN)
4050118392777
Qty.
1 pc(s).
Depth
76 mm
Depth (inches)
2.992 inch
Height
120 mm
Height (inches)
4.724 inch
Width
11.5
Width (inches)
0.453 inch
Mounting dimension - height
128 mm
Net weight
90 g
Storage temperature
-40 °C ... +85 °C
Operating temperature
-20 °C ... +60 °C
REACH SVHC
Lead 7439-92-1
SCIP
82327f13-cd27-455a-ab5b-a62e1996dcf8
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Analysis of harmonic
31 (Blackmann-Harris Window)
Category for voltage measurements
CAT II (IEC 61010 Part 1)
Connectable converter ratios
1 … 1000
Frequency of the supply system
45…65 Hz
Input impedance voltage
2.4 MΩ per channel
Insulation
1.5 kVeff. (input / system)
Measurement accuracy
0.5% in relation to final value (U / I), 1% for the calculated values
Measurement method
High Resolution Delta Sigma (current measurement in outer conductor)
Measurement resistance (shunt)
4 mΩ (at 5 A), 20 mΩ (at 1 A)
Module diagnosis
Yes
Nominal peak voltage
4 kV
Number
3
Power rating
0…1 A / 0…5 A AC
Rated voltage
300 Veff (L-N), 520 Veff (L-L)
Resolution
16 bit per channel (internal 24 bit)
Sampling rate of current measurement
3,300 samples/s
Number
3
Type of connection
PUSH IN
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire connection cross section, finely stranded, min.
0.14 mm²
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, max. (AWG)
AWG 16
Wire cross-section, solid, min.
0.14 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Air humidity (operation)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport)
10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation)
≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity
2
Rail
TS 35
Shock
15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category
II
Test voltage
500 V
UL 94 flammability rating
V-0
Vibration resistance
5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Current consumption from IIN (the respective power segment)
12 mA
Current consumption from Isys , typ.
8 mA
Voltage supply
24 V DC +20 %/ -15 %, via the system bus
Configuration interface
Micro USB 2.0
Field bus protocol
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
Galvanic isolation
500 V DC between the current paths
Interface
u-remote system bus
Module type
Functional module
Process data
32 Byte
Transmission speed of system bus, max.
48 Mbit
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Product Change Notification
Software
User Documentation
Catalogues
Catalogues in PDF-format
ETIM 6.0
EC001601
ETIM 7.0
EC001601
ETIM 8.0
EC001601
ETIM 9.0
EC001601
ECLASS 9.0
27-24-26-05
ECLASS 9.1
27-24-26-05
ECLASS 10.0
27-24-26-05
ECLASS 11.0
27-24-26-05
ECLASS 12.0
27-24-26-05
ECLASS 13.0
27-24-26-05
ECLASS 14.0
27-24-26-05
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Certificate no. (cULusEX)
E223527
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.