Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
General ordering data
Version
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus, Input : 0…40/50/60 A, Output : Pulse
Order No.
1510370000
Type
ACT20C-GTW-100-MTCP-S
GTIN (EAN)
4050118319606
Qty.
1 pc(s).
Dimensions and weights
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
150 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...60 °C
Humidity
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
160 a
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Communication
Addressing
DHCP or manual adjustment
Configuration
With FDT/DTM software, DHCP
Interface
Communication via CH20M rail bus with all current measuring transducers (ACT20C-CMT-x)
Number of devices on the bus, max.
16
Protocol
Modbus/TCP, DHCP Server/Client
RJ45 ports
10/100BaseT(X), auto negotiation
Interface 1
Addressing
DHCP or manual adjustment
Interface
Communication via CH20M rail bus with all current measuring transducers (ACT20C-CMT-x)
Number of devices on the bus, max.
16
Protocol
Modbus/TCP, DHCP Server/Client
General data
Configuration
With FDT/DTM software, DHCP
Power consumption, max.
1.5 W
Protection degree
IP20
Rail
TS 35
Voltage supply
18.0 … 31.2 V DC
Insulation coordination
EMC standards
IEC 61326-1
Impulse withstand voltage
0,5 kV (1.2/50 μs)
Pollution severity
2
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional earth to supply ⁄ Ethernet interface
30 V AC RMS
Surge voltage category
II
Test voltage
1.1 kV
Connection data
Type of connection
Screw connection, RJ45 plug-in connector
Tightening torque, min.
0.5 Nm
Tightening torque, max.
3.5 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Important note
Product information
The ACT20C-GTW-100-MTCP-S gateway is a modbus TCP slave in accordance with IEC 61158. It connects ACT20C devices to an Ethernet network for diagnostic, configuration and status monitoring purposes.
Properties
RJ45 port with Ethernet TCP/IP
Jack socket for direct point-to-point communication via a CBX200 USB adapter
Configuration using the standard FDT/DTM
Station management with “Plug & Produce” and “Hot Swapping”
Operational status and error display on a front panel LED according to NE44, NE107
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Brochures
Classifications
ETIM 6.0
EC002475
ETIM 7.0
EC002475
ETIM 8.0
EC002475
ETIM 9.0
EC002475
ECLASS 9.0
27-21-01-23
ECLASS 9.1
27-21-01-23
ECLASS 10.0
27-21-01-23
ECLASS 11.0
27-21-01-23
ECLASS 12.0
27-21-01-23
ECLASS 13.0
27-21-01-23
ECLASS 14.0
27-21-01-23
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Type of connection:
Screw connection
Order No.:
2044840000
Type:
ACT20C-CML-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510240000
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510420000
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
socket / socket
Order No.:
1510340000
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
Version
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus, Input : 0…40/50/60 A, Output : Pulse
Order No.
1510370000
Type
ACT20C-GTW-100-MTCP-S
GTIN (EAN)
4050118319606
Qty.
1 pc(s).
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
150 g
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...60 °C
Humidity
5...95 %, no condensation
SIL in compliance with IEC 61508
None
MTTF
160 a
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Addressing
DHCP or manual adjustment
Configuration
With FDT/DTM software, DHCP
Interface
Communication via CH20M rail bus with all current measuring transducers (ACT20C-CMT-x)
Number of devices on the bus, max.
16
Protocol
Modbus/TCP, DHCP Server/Client
RJ45 ports
10/100BaseT(X), auto negotiation
Addressing
DHCP or manual adjustment
Interface
Communication via CH20M rail bus with all current measuring transducers (ACT20C-CMT-x)
Number of devices on the bus, max.
16
Protocol
Modbus/TCP, DHCP Server/Client
Configuration
With FDT/DTM software, DHCP
Power consumption, max.
1.5 W
Protection degree
IP20
Rail
TS 35
Voltage supply
18.0 … 31.2 V DC
EMC standards
IEC 61326-1
Impulse withstand voltage
0,5 kV (1.2/50 μs)
Pollution severity
2
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional earth to supply ⁄ Ethernet interface
30 V AC RMS
Surge voltage category
II
Test voltage
1.1 kV
Type of connection
Screw connection, RJ45 plug-in connector
Tightening torque, min.
0.5 Nm
Tightening torque, max.
3.5 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Product information
The ACT20C-GTW-100-MTCP-S gateway is a modbus TCP slave in accordance with IEC 61158. It connects ACT20C devices to an Ethernet network for diagnostic, configuration and status monitoring purposes.
Properties
RJ45 port with Ethernet TCP/IP
Jack socket for direct point-to-point communication via a CBX200 USB adapter
Configuration using the standard FDT/DTM
Station management with “Plug & Produce” and “Hot Swapping”
Operational status and error display on a front panel LED according to NE44, NE107
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Brochures
ETIM 6.0
EC002475
ETIM 7.0
EC002475
ETIM 8.0
EC002475
ETIM 9.0
EC002475
ECLASS 9.0
27-21-01-23
ECLASS 9.1
27-21-01-23
ECLASS 10.0
27-21-01-23
ECLASS 11.0
27-21-01-23
ECLASS 12.0
27-21-01-23
ECLASS 13.0
27-21-01-23
ECLASS 14.0
27-21-01-23
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Type of connection:
Screw connection
Order No.:
2044840000
Type:
ACT20C-CML-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510240000
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
Screw connection
Order No.:
1510420000
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Type of connection:
socket / socket
Order No.:
1510340000
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.