Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Switched-mode power supply units
Electronic load monitoring
Communication modules
Uninterruptible power supply
DC/DC converter
Diode- and redundancy modules
Pre charge unit
Decentralised switched-mode power supply units IP65
Decentralised electronic load monitoring IP65
Accessories
Capacity modules
Diode modules
Redundancy modules
General ordering data
Version
Capacity module
Order No.
1222240010
Type
CP M CAP
GTIN (EAN)
4050118176148
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-10-31
Dimensions and weights
Depth
150 mm
Depth (inches)
5.905 inch
Height
130 mm
Height (inches)
5.118 inch
Width
34 mm
Width (inches)
1.339 inch
Net weight
633 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70 °C
Humidity
5...95 %, no condensation
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
c9dca554-f123-4c2f-a680-5a7631aa9527
Input
DC current consumption
25 mA @24 V after charging process
DC input voltage range
18…30 V DC
Rated input voltage
24 V DC
Wire connection method
Screw connection
Output
Peak current output
load dependent (typ. 40 A for 1 ms)
Recovery time for the capacitor
Approx. 1 sec.
Switching thresholds
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail
Voltage monitoring
Yes
Wire connection method
Screw connection
General data
Clip-in foot
metal
Humidity
5...95 %, no condensation
MTBF
According to Standard
SN 29500
Operating time (hours), min.
7,390,000 h
Ambient temperature
25 °C
Input voltage
24 V
Duty cycle
100 %
According to Standard
SN 29500
Operating time (hours), min.
3,249,000 h
Ambient temperature
40 °C
Input voltage
24 V
Duty cycle
100 %
Mounting position, installation notice
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Power loss, idling
600 mW
Protection degree
IP20
EMC / shock / vibration
Interference immunity test acc. to
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips)
Noise emission in accordance with EN55032
Class B
Shock resistance IEC 60068-2-27
15 g In all directions
Vibration resistance IEC 60068-2-6
1 g according to EN 50178
Insulation coordination
Insulation voltage
0.5 kV Input / output - Box
Pollution severity
2
Protection class
III, with no ground connection, for SELV
Electrical safety (applied standards)
Electrical machine equipment
Acc. to EN60204
For use with electronic equipment
Acc. to EN50178 / VDE0160
Connection data (input)
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
4 (++--)
Wire connection cross section, flexible (input), max.
4 mm²
Connection data (output)
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
3 (CO contacts)
Signalling
Floating contact
Yes
Approbations
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
Classifications
ETIM 6.0
EC002850
ETIM 7.0
EC002850
ETIM 8.0
EC002850
ETIM 9.0
EC002850
ECLASS 9.0
27-04-06-92
ECLASS 9.1
27-04-92-01
ECLASS 10.0
27-04-06-92
ECLASS 11.0
27-04-06-92
ECLASS 12.0
27-04-06-92
ECLASS 13.0
27-04-06-92
Version
Capacity module
Order No.
1222240010
Type
CP M CAP
GTIN (EAN)
4050118176148
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-10-31
Depth
150 mm
Depth (inches)
5.905 inch
Height
130 mm
Height (inches)
5.118 inch
Width
34 mm
Width (inches)
1.339 inch
Net weight
633 g
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70 °C
Humidity
5...95 %, no condensation
REACH SVHC
Lead 7439-92-1
SCIP
c9dca554-f123-4c2f-a680-5a7631aa9527
DC current consumption
25 mA @24 V after charging process
DC input voltage range
18…30 V DC
Rated input voltage
24 V DC
Wire connection method
Screw connection
Peak current output
load dependent (typ. 40 A for 1 ms)
Recovery time for the capacitor
Approx. 1 sec.
Switching thresholds
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail
Voltage monitoring
Yes
Wire connection method
Screw connection
Clip-in foot
metal
Humidity
5...95 %, no condensation
MTBF
According to Standard
SN 29500
Operating time (hours), min.
7,390,000 h
Ambient temperature
25 °C
Input voltage
24 V
Duty cycle
100 %
According to Standard
SN 29500
Operating time (hours), min.
3,249,000 h
Ambient temperature
40 °C
Input voltage
24 V
Duty cycle
100 %
Mounting position, installation notice
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Power loss, idling
600 mW
Protection degree
IP20
Interference immunity test acc. to
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips)
Noise emission in accordance with EN55032
Class B
Shock resistance IEC 60068-2-27
15 g In all directions
Vibration resistance IEC 60068-2-6
1 g according to EN 50178
Insulation voltage
0.5 kV Input / output - Box
Pollution severity
2
Protection class
III, with no ground connection, for SELV
Electrical machine equipment
Acc. to EN60204
For use with electronic equipment
Acc. to EN50178 / VDE0160
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
4 (++--)
Wire connection cross section, flexible (input), max.
4 mm²
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
3 (CO contacts)
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
ETIM 6.0
EC002850
ETIM 7.0
EC002850
ETIM 8.0
EC002850
ETIM 9.0
EC002850
ECLASS 9.0
27-04-06-92
ECLASS 9.1
27-04-92-01
ECLASS 10.0
27-04-06-92
ECLASS 11.0
27-04-06-92
ECLASS 12.0
27-04-06-92
ECLASS 13.0
27-04-06-92
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E258476
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.