Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Miniature Circuit Breaker
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
Protection for analogue signals (CL)
Protection for binary signals (SL)
VSSC Application
1-level protection with varistor (MOV)
1-level protection with gas discharge tubes (GDT)
1-level protection with suppressor circuit (RC combination with MOV)
1-level protection with suppressor diodes (TAZ)
Accessories (end plates)
VSSC with gas discharge tubes (GDT)
VSSC4 surge protection terminal with gas discharge tube
VSSC6 surge protection terminal with gas discharge tube
General ordering data
Version
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Order No.
1064870000
Type
VSSC6TRGDT24VAC/DC10KA
GTIN (EAN)
4032248830121
Qty.
10 pc(s).
Dimensions and weights
Depth
81 mm
Depth (inches)
3.189 inch
Height
88.5 mm
Height (inches)
3.484 inch
Width
6.2 mm
Width (inches)
0.244 inch
Net weight
43.6 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...80
Humidity
5...96 %
Probability of failure
SIL in compliance with IEC 61508
3
MTTF
11,416 a
SFF
100 %
λges
10
PFH in 1*10-9 per hour
0
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
CSA protection data
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. II
12 A
Input voltage, max. Ui
42 V
Internal capacity, max. CI
0 nF
Internal inductance, max. LI
0 µH
General data
Number of poles
1
Protection degree
IP20
Colour
black
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Capacitance
1.5 nF
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current, max. (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
1 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
1 kA
Max. continuous voltage, Uc (AC)
30 V
Max. continuous voltage, Uc (DC)
42 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
< 1000 V
Rated current IN
12 A
Rated voltage (AC)
24 V
Rated voltage (DC)
34 V
Requirements category acc. to IEC 61643-21
C2, C3, D1
Standards
IEC 61643-21
Surge current-carrying capacity C2
2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3
50 A 10/1000 μs
Surge current-carrying capacity D1
1 kA 10/350 μs
Voltage type
AC/DC
Volume resistance
<0.1 Ω
Connection data
Stripping length
10 mm
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²
Electrical data
Voltage type
AC/DC
Important note
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Tender specification sheets
Long specification
Feed-through terminal, 12.4mm wide with sparkover gap between the two signal lines and the mounting rail potential, TS 35 contact base.Each signal path can be opened using an isolator.A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification
Feed-through terminal with sparkover gaps (GDT) between two signal lines and mounting rail potential. Each signal path can be opened using an isolator.TS 35 contact base. Version: 24 V UC 10kA
Type of connection:
Screw connection
Order No.:
1064690000
Type:
VSSC6 GDT 110VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064700000
Type:
VSSC6 GDT 110VAC/DC20KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Type of connection:
Screw connection
Order No.:
1064710000
Type:
VSSC6 GDT 240VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
Type of connection:
Screw connection
Order No.:
1064720000
Type:
VSSC6 GDT 240VAC/DC20KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
Type of connection:
Screw connection
Order No.:
1064640000
Type:
VSSC6 GDT 24VAC/DC 10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Type of connection:
Screw connection
Order No.:
1064890000
Type:
VSSC6TRGDT110VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064920000
Type:
VSSC6TRGDT240VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
Version
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Order No.
1064870000
Type
VSSC6TRGDT24VAC/DC10KA
GTIN (EAN)
4032248830121
Qty.
10 pc(s).
Depth
81 mm
Depth (inches)
3.189 inch
Height
88.5 mm
Height (inches)
3.484 inch
Width
6.2 mm
Width (inches)
0.244 inch
Net weight
43.6 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...80
Humidity
5...96 %
SIL in compliance with IEC 61508
3
MTTF
11,416 a
SFF
100 %
λges
10
PFH in 1*10-9 per hour
0
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. II
12 A
Input voltage, max. Ui
42 V
Internal capacity, max. CI
0 nF
Internal inductance, max. LI
0 µH
Number of poles
1
Protection degree
IP20
Colour
black
Pollution severity
2
Surge voltage category
III
Capacitance
1.5 nF
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current, max. (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
1 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
1 kA
Max. continuous voltage, Uc (AC)
30 V
Max. continuous voltage, Uc (DC)
42 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
< 1000 V
Rated current IN
12 A
Rated voltage (AC)
24 V
Rated voltage (DC)
34 V
Requirements category acc. to IEC 61643-21
C2, C3, D1
Standards
IEC 61643-21
Surge current-carrying capacity C2
2.5 kA 8/20 µs 5 kV 1.2/50 µs
Surge current-carrying capacity C3
50 A 10/1000 μs
Surge current-carrying capacity D1
1 kA 10/350 μs
Voltage type
AC/DC
Volume resistance
<0.1 Ω
Stripping length
10 mm
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Long specification
Feed-through terminal, 12.4mm wide with sparkover gap between the two signal lines and the mounting rail potential, TS 35 contact base.Each signal path can be opened using an isolator.A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification
Feed-through terminal with sparkover gaps (GDT) between two signal lines and mounting rail potential. Each signal path can be opened using an isolator.TS 35 contact base. Version: 24 V UC 10kA
Type of connection:
Screw connection
Order No.:
1064690000
Type:
VSSC6 GDT 110VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064700000
Type:
VSSC6 GDT 110VAC/DC20KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Type of connection:
Screw connection
Order No.:
1064710000
Type:
VSSC6 GDT 240VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
Type of connection:
Screw connection
Order No.:
1064720000
Type:
VSSC6 GDT 240VAC/DC20KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
Type of connection:
Screw connection
Order No.:
1064640000
Type:
VSSC6 GDT 24VAC/DC 10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 1000 V
Type of connection:
Screw connection
Order No.:
1064890000
Type:
VSSC6TRGDT110VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064920000
Type:
VSSC6TRGDT240VAC/DC10KA
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1900 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.