Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
Protection for analogue signals (CL)
Protection for binary signals (SL)
VSSC Application
1-level protection with varistor (MOV)
1-level protection with gas discharge tubes (GDT)
1-level protection with suppressor circuit (RC combination with MOV)
1-level protection with suppressor diodes (TAZ)
Accessories (end plates)
VSSC4 surge protection terminal with varistor (MOV)
VSSC4 surge protection terminal with varistor (12 V, 24 V, 48 V, 60 V, 120 V, 150 V and 240 V MOV)
VSSC6 surge protection terminal with varistor (12 V, 24 V, 48 V, 60 V, 120 V, 150 V and 240 V MOV)
General ordering data
Version
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 150 V
Order No.
1064540000
Type
VSSC6 MOV 24VAC/DC
GTIN (EAN)
4032248829873
Qty.
8 pc(s).
Dimensions and weights
Depth
81 mm
Depth (inches)
3.189 inch
Height
88.5 mm
Height (inches)
3.484 inch
Width
7.2 mm
Width (inches)
0.283 inch
Net weight
50.75 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
Probability of failure
SIL in compliance with IEC 61508
3
MTTF
4,391 a
SFF
100 %
λges
26
PFH in 1*10-9 per hour
0
Environmental Product Compliance
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Rated data UL
Certificate No. (UL)
E311081
UL certificate
UL Zertifikat
CSA protection data
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. II
12 A
Input voltage, max. Ui
42 V
Internal capacity, max. CI
10 nF
Internal inductance, max. LI
0 µH
General data
Colour
black
Design
Terminal
Isolating function
No
Optical function display
No
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Capacitance
4.6 nF
Discharge current Imax (8/20µs) wire-PE
1 kA
Discharge current In (8/20µs) wire-PE
0.5 kA
Discharge current, max. (8/20 µs)
2 kA
Insertion loss
≤ 1.0 dB
Max. continuous voltage, Uc (AC)
30 V
Max. continuous voltage, Uc (DC)
42 V
Number of poles
1
Overload - failure mode
Mode 1
Protection level UP (typ.)
150 V
Rated current IN
12 A
Rated voltage (AC)
24 V
Rated voltage (DC)
34 V
Requirements category acc. to IEC 61643-21
C1
Standards
According to IEC61643-21
Surge current-carrying capacity C1
0.25 kA 8/20 µs 0.5 kV 1.2/50 µs
Voltage type
AC/DC
Volume resistance
<0.1 Ω
Connection data
Stripping length
10 mm
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²
Important note
Product information
Mode 1: State where the voltage-limiting part of the SPD was disconnected. The voltage limiting function is no longer available, but the cable is still functional.
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Tender specification sheets
Long specification
Feed-through terminal, 6.2mm wide with varistors between the two signal lines and the mounting rail potential, TS 35 contact base. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification
Feed-through terminal with varistors (MOV) between two signal lines and the mounting rail potential, TS 35 contact base. Version: 24 V UC
Type of connection:
Screw connection
Order No.:
1064610000
Type:
VSSC6 MOV 120VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 600 V
Type of connection:
Screw connection
Order No.:
1064530000
Type:
VSSC6 MOV 12VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 100 V
Type of connection:
Screw connection
Order No.:
1064630000
Type:
VSSC6 MOV 240VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064570000
Type:
VSSC6 MOV 48VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 250 V
Type of connection:
Screw connection
Order No.:
1064600000
Type:
VSSC6 MOV 60VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 300 V
Type of connection:
Screw connection
Order No.:
1064800000
Type:
VSSC6 TRLDMOV 12VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 100 V
Type of connection:
Screw connection
Order No.:
1064810000
Type:
VSSC6 TRLDMOV 24VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 150 V
Type of connection:
Screw connection
Order No.:
1064820000
Type:
VSSC6 TRLDMOV 48VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 250 V
Type of connection:
Screw connection
Order No.:
1064840000
Type:
VSSC6 TRLDMOV120VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 600 V
Type of connection:
Screw connection
Order No.:
1064860000
Type:
VSSC6 TRLDMOV240VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Version
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 150 V
Order No.
1064540000
Type
VSSC6 MOV 24VAC/DC
GTIN (EAN)
4032248829873
Qty.
8 pc(s).
Depth
81 mm
Depth (inches)
3.189 inch
Height
88.5 mm
Height (inches)
3.484 inch
Width
7.2 mm
Width (inches)
0.283 inch
Net weight
50.75 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
SIL in compliance with IEC 61508
3
MTTF
4,391 a
SFF
100 %
λges
26
PFH in 1*10-9 per hour
0
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. II
12 A
Input voltage, max. Ui
42 V
Internal capacity, max. CI
10 nF
Internal inductance, max. LI
0 µH
Colour
black
Design
Terminal
Isolating function
No
Optical function display
No
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control
Pollution severity
2
Surge voltage category
III
Capacitance
4.6 nF
Discharge current Imax (8/20µs) wire-PE
1 kA
Discharge current In (8/20µs) wire-PE
0.5 kA
Discharge current, max. (8/20 µs)
2 kA
Insertion loss
≤ 1.0 dB
Max. continuous voltage, Uc (AC)
30 V
Max. continuous voltage, Uc (DC)
42 V
Number of poles
1
Overload - failure mode
Mode 1
Protection level UP (typ.)
150 V
Rated current IN
12 A
Rated voltage (AC)
24 V
Rated voltage (DC)
34 V
Requirements category acc. to IEC 61643-21
C1
Standards
According to IEC61643-21
Surge current-carrying capacity C1
0.25 kA 8/20 µs 0.5 kV 1.2/50 µs
Voltage type
AC/DC
Volume resistance
<0.1 Ω
Stripping length
10 mm
Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²
Product information
Mode 1: State where the voltage-limiting part of the SPD was disconnected. The voltage limiting function is no longer available, but the cable is still functional.
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Long specification
Feed-through terminal, 6.2mm wide with varistors between the two signal lines and the mounting rail potential, TS 35 contact base. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification
Feed-through terminal with varistors (MOV) between two signal lines and the mounting rail potential, TS 35 contact base. Version: 24 V UC
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UL)
E311081
Type of connection:
Screw connection
Order No.:
1064610000
Type:
VSSC6 MOV 120VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 600 V
Type of connection:
Screw connection
Order No.:
1064530000
Type:
VSSC6 MOV 12VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 100 V
Type of connection:
Screw connection
Order No.:
1064630000
Type:
VSSC6 MOV 240VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
Type of connection:
Screw connection
Order No.:
1064570000
Type:
VSSC6 MOV 48VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 250 V
Type of connection:
Screw connection
Order No.:
1064600000
Type:
VSSC6 MOV 60VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 300 V
Type of connection:
Screw connection
Order No.:
1064800000
Type:
VSSC6 TRLDMOV 12VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 100 V
Type of connection:
Screw connection
Order No.:
1064810000
Type:
VSSC6 TRLDMOV 24VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 150 V
Type of connection:
Screw connection
Order No.:
1064820000
Type:
VSSC6 TRLDMOV 48VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) 250 V
Type of connection:
Screw connection
Order No.:
1064840000
Type:
VSSC6 TRLDMOV120VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) < 600 V
Type of connection:
Screw connection
Order No.:
1064860000
Type:
VSSC6 TRLDMOV240VAC/DC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control, UP (L/N-PE) ≤ 1200 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.