Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible measuring transducer - ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
A/D converter
D/A converter
RS D8-U 0...10V
Do not use product for new developmentsOnly remaining stock available
General ordering data
Version
DA converter, Input : 8-bit pulse, Output : 0-10 V
Order No.
1160761001
Type
RS D8-U 0...10V
GTIN (EAN)
4032248101245
Qty.
1 pc(s).
Available until
2024-06-30
Dimensions and weights
Depth
70 mm
Depth (inches)
2.756 inch
Height
72 mm
Height (inches)
2.835 inch
Width
35 mm
Width (inches)
1.378 inch
Net weight
72 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
0 °C...50 °C
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
7b5ffb72-271d-4c73-8b09-bd0aaee3697a
Input
Input resistance, voltage
50 kΩ per input
Number of inputs
8-bit (1-bit signed)
Rated input level
5…24 V DC = High, 0 V DC = Low, max. 30 V = High
Output
Conversion time
≤ 30 µs
Number of outputs
1
Offset voltage
≤ 20 mV
Output current
≤ 10 mA max. current
Output voltage, note
0...10 V
load impedance voltage
≥ 1 kΩ
General data
Accuracy
± 1 LSB
Current consumption
25 mA (plus output current)
Galvanic isolation
Without isolation
Protection degree
IP00
Rail
TS 35, TS 32
Voltage supply
24 V DC
Insulation coordination
EMC standards
EN 61000-6
Galvanic isolation
Without isolation
Connection data
Type of connection
Screw connection
Clamping range, rated connection
4 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-90
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
Approvals
ROHS
Conform
Order No.:
1165861001
Type of connection:
Screw connection
Type:
RS D8-I 0...20MA
Version:
DA converter, Input : 8-bit pulse, Output : 0-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
1169261001
Type of connection:
Screw connection
Type:
RS D8-I 4...20MA
Version:
DA converter, Input : 8-bit pulse, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
1123361001
Type of connection:
Screw connection
Type:
RS D8-U +-10V
Version:
DA converter, Input : 8-bit pulse, Output : -10…0…+10 V
Delivery status:
This article will no longer be available in the future.
Version
DA converter, Input : 8-bit pulse, Output : 0-10 V
Order No.
1160761001
Type
RS D8-U 0...10V
GTIN (EAN)
4032248101245
Qty.
1 pc(s).
Available until
2024-06-30
Depth
70 mm
Depth (inches)
2.756 inch
Height
72 mm
Height (inches)
2.835 inch
Width
35 mm
Width (inches)
1.378 inch
Net weight
72 g
Storage temperature
-40 °C...80 °C
Operating temperature
0 °C...50 °C
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
7b5ffb72-271d-4c73-8b09-bd0aaee3697a
Input resistance, voltage
50 kΩ per input
Number of inputs
8-bit (1-bit signed)
Rated input level
5…24 V DC = High, 0 V DC = Low, max. 30 V = High
Conversion time
≤ 30 µs
Number of outputs
1
Offset voltage
≤ 20 mV
Output current
≤ 10 mA max. current
Output voltage, note
0...10 V
load impedance voltage
≥ 1 kΩ
Accuracy
± 1 LSB
Current consumption
25 mA (plus output current)
Galvanic isolation
Without isolation
Protection degree
IP00
Rail
TS 35, TS 32
Voltage supply
24 V DC
EMC standards
EN 61000-6
Galvanic isolation
Without isolation
Type of connection
Screw connection
Clamping range, rated connection
4 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-90
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
Order No.:
1165861001
Type of connection:
Screw connection
Type:
RS D8-I 0...20MA
Version:
DA converter, Input : 8-bit pulse, Output : 0-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
1169261001
Type of connection:
Screw connection
Type:
RS D8-I 4...20MA
Version:
DA converter, Input : 8-bit pulse, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
1123361001
Type of connection:
Screw connection
Type:
RS D8-U +-10V
Version:
DA converter, Input : 8-bit pulse, Output : -10…0…+10 V
Delivery status:
This article will no longer be available in the future.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.