TC measurement isolating transformer, configured with DIP switches, 2-way isolation TC measurement isolating transformer in 6.1 mm width with external power supply, for recording, transmitting and isolating thermocouple signals of type J, in compliance with IEC 564. Analogue DC signals 0(4)...20 mA /0...5 V/ 0...10 V are available on the output side. The input/output circuits have 500 Veff of electrical isolation. The output is used to supply 24 VDC. Add-on housing for TS35 rail mounting Dimensions: L/W/H 92/ 6.1/ 97.8 mm Tension-clamp connection / Nominal cross-section 1.5 mm2 Protection degree: IP 20
Input thermocouples, type J / IEC 584 0...700 °C Output 0/4...20 mA 0...5 V, 0...10 V Load resistance < 400 Ohm/ Strom/> 10 kOhm/ voltage Transmission error < 0,7 % v. E. typ. 250 ppm / °C Step response time < 0,7 s Auxiliary power 24 VDC +/- 10 % Power loss approx. 0.6 W Ambient temperature range 0°C...+55 °C Isolation EN 50178, 2-way isolation up to 500 V AC/DC Rated voltage 100 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus
TypeMAZ Thermo-J 0...700C
Short specification
TC measurement isolating transformer, configured with DIP switches, 2-way isolation TC measurement isolating transformer in 6.1 mm width with external power supply, for recording, transmitting and isolating thermocouple signals of type J, in compliance with IEC 564. Analogue DC signals 0(4)...20 mA /0...5 V/ 0...10 V are available on the output side. The input/output circuits have 500 Veff of electrical isolation. The output is used to supply 24 VDC.
TC measurement isolating transformer, configured with DIP switches, 2-way isolation TC measurement isolating transformer in 6.1 mm width with external power supply, for recording, transmitting and isolating thermocouple signals of type J, in compliance with IEC 564. Analogue DC signals 0(4)...20 mA /0...5 V/ 0...10 V are available on the output side. The input/output circuits have 500 Veff of electrical isolation. The output is used to supply 24 VDC. Add-on housing for TS35 rail mounting Dimensions: L/W/H 92/ 6.1/ 97.8 mm Tension-clamp connection / Nominal cross-section 1.5 mm2 Protection degree: IP 20
Input thermocouples, type J / IEC 584 0...700 °C Output 0/4...20 mA 0...5 V, 0...10 V Load resistance < 400 Ohm/ Strom/> 10 kOhm/ voltage Transmission error < 0,7 % v. E. typ. 250 ppm / °C Step response time < 0,7 s Auxiliary power 24 VDC +/- 10 % Power loss approx. 0.6 W Ambient temperature range 0°C...+55 °C Isolation EN 50178, 2-way isolation up to 500 V AC/DC Rated voltage 100 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus
TypeMAZ Thermo-J 0...700C
Short specification
TC measurement isolating transformer, configured with DIP switches, 2-way isolation TC measurement isolating transformer in 6.1 mm width with external power supply, for recording, transmitting and isolating thermocouple signals of type J, in compliance with IEC 564. Analogue DC signals 0(4)...20 mA /0...5 V/ 0...10 V are available on the output side. The input/output circuits have 500 Veff of electrical isolation. The output is used to supply 24 VDC.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.