Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Signal - & serial interface converter– WAVESERIES
Process monitoring displays
Analogue-digital / digital-analogue converter
Configuration software
Accessories
Frequency signal converter
Limit-value monitoring
Passive isolator
Temperature transducer
Limit- & current monitoring
Logic modules
General ordering data
Version
DC/f transformer, Input : 4-20 mA, Output frequency: 0...1/ 4/ 8/ 16 kHz
Order No.
8461490000
Type
MCZ CFC 4-20MA
GTIN (EAN)
4032248037797
Qty.
10 pc(s).
Dimensions and weights
Depth
63.2 mm
Depth (inches)
2.488 inch
Width
6 mm
Width (inches)
0.236 inch
Length
91 mm
Length (inches)
3.583 inch
Net weight
27.5 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
0 °C...60 °C
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
c2a21576-d875-4548-ae68-5e7f85ddf0c7
Input
Input current
4...20 mA
Input resistance, current
50 Ω
Number of inputs
1
Voltage drop
5.8...6.4 V at 20 mA
Output
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
max. 20 mA
Output frequency
0...1/ 4/ 8/ 16 kHz
Output level
PNP, Ub-0.7 V
General data
Accuracy
0.15 % v. FSR
Current consumption
14 mA without load
Galvanic isolation
between input ⁄ output ⁄ supply
Long-term drift
0
Rail
TS 35
Temperature coefficient
≤ 250 ppm/K
Voltage supply
24 V DC ± 10 %
Insulation coordination
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
between input ⁄ output ⁄ supply
Impulse withstand voltage
1.5 kV
Insulation voltage
1 kV DC
Insulation voltage input or output/rail
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
100 V
Surge voltage category
III
Test voltage
0.3 kV
Connection data
Type of connection
Tension-clamp connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Classifications
ETIM 6.0
EC002918
ETIM 7.0
EC002918
ETIM 8.0
EC002918
ETIM 9.0
EC002918
ECLASS 9.0
27-21-01-28
ECLASS 9.1
27-21-01-28
ECLASS 10.0
27-21-01-28
ECLASS 11.0
27-21-01-28
ECLASS 12.0
27-21-01-28
ECLASS 13.0
27-21-01-28
Approvals
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8461470000
Type:
MCZ VFC 0-10V
Version:
DC/f transformer, Input : 0-10 V, Output frequency: 0...1/ 4/ 8/ 16 kHz
Type of connection:
Tension-clamp connection
Order No.:
8461480000
Type:
MCZ CFC 0-20MA
Version:
DC/f transformer, Input : 0-20 mA, Output frequency: 0...1/ 4/ 8/ 16 kHz
Type of connection:
Screw connection
Order No.:
8242040000
Type:
DK U-F DK5 0-10V
Version:
DC/f transformer, Input : 0-10 V, Output : Frequency, 0...1/ 4/ 8/ 16 kHz
Type of connection:
Screw connection
Order No.:
8283810001
Type:
DK F-U DK5 0-16KHZ 24V
Version:
Frequency signal converter, Input : Frequency, 0...50/ 100/ 500 Hz; 0...1/ 5/ 10/ 16 kHz, Output : 0-10 V
Version
DC/f transformer, Input : 4-20 mA, Output frequency: 0...1/ 4/ 8/ 16 kHz
Order No.
8461490000
Type
MCZ CFC 4-20MA
GTIN (EAN)
4032248037797
Qty.
10 pc(s).
Depth
63.2 mm
Depth (inches)
2.488 inch
Width
6 mm
Width (inches)
0.236 inch
Length
91 mm
Length (inches)
3.583 inch
Net weight
27.5 g
Storage temperature
-20 °C...85 °C
Operating temperature
0 °C...60 °C
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
c2a21576-d875-4548-ae68-5e7f85ddf0c7
Input current
4...20 mA
Input resistance, current
50 Ω
Number of inputs
1
Voltage drop
5.8...6.4 V at 20 mA
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
max. 20 mA
Output frequency
0...1/ 4/ 8/ 16 kHz
Output level
PNP, Ub-0.7 V
Accuracy
0.15 % v. FSR
Current consumption
14 mA without load
Galvanic isolation
between input ⁄ output ⁄ supply
Long-term drift
0
Rail
TS 35
Temperature coefficient
≤ 250 ppm/K
Voltage supply
24 V DC ± 10 %
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
between input ⁄ output ⁄ supply
Impulse withstand voltage
1.5 kV
Insulation voltage
1 kV DC
Insulation voltage input or output/rail
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
100 V
Surge voltage category
III
Test voltage
0.3 kV
Type of connection
Tension-clamp connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
ETIM 6.0
EC002918
ETIM 7.0
EC002918
ETIM 8.0
EC002918
ETIM 9.0
EC002918
ECLASS 9.0
27-21-01-28
ECLASS 9.1
27-21-01-28
ECLASS 10.0
27-21-01-28
ECLASS 11.0
27-21-01-28
ECLASS 12.0
27-21-01-28
ECLASS 13.0
27-21-01-28
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8461470000
Type:
MCZ VFC 0-10V
Version:
DC/f transformer, Input : 0-10 V, Output frequency: 0...1/ 4/ 8/ 16 kHz
Type of connection:
Tension-clamp connection
Order No.:
8461480000
Type:
MCZ CFC 0-20MA
Version:
DC/f transformer, Input : 0-20 mA, Output frequency: 0...1/ 4/ 8/ 16 kHz
Type of connection:
Screw connection
Order No.:
8242040000
Type:
DK U-F DK5 0-10V
Version:
DC/f transformer, Input : 0-10 V, Output : Frequency, 0...1/ 4/ 8/ 16 kHz
Type of connection:
Screw connection
Order No.:
8283810001
Type:
DK F-U DK5 0-16KHZ 24V
Version:
Frequency signal converter, Input : Frequency, 0...50/ 100/ 500 Hz; 0...1/ 5/ 10/ 16 kHz, Output : 0-10 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.