Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Signal - & serial interface converter– WAVESERIES
Process monitoring displays
Analogue-digital / digital-analogue converter
Configuration software
Accessories
Process value indicators with LCD display - ACT20D
Process value indicators with LED display - ACT20D
Process value indicators with LED display
PMX420PLUS DC CE
Do not use product for new developments
General ordering data
Version
Input, Current/Voltage, Analogue output, Relay output
Order No.
7940018957
Type
PMX420PLUS DC CE
GTIN (EAN)
4032248594221
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-03-28
Alternative product
2920060000
Dimensions and weights
Height
48.8 mm
Height (inches)
1.921 inch
Width
96.6 mm
Width (inches)
3.803 inch
Length
137 mm
Length (inches)
5.394 inch
Net weight
442.06 g
Temperatures
Storage temperature
-25 °C...70 °C
Operating temperature
0 °C...60 °C
Humidity
0...90 % (no condensation)
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
Display
Display range
-9999...9999
Display value
Percentage or real value display
Scaling
Variable
Type
4-digit, red LED, 14.2 mm
General data
Cut-off frequency (-3 dB)
5 Hz
Input/Output
Voltage/current input
Linearity
< 0.05 %
Long-term drift
0.1 % / 10.000 h
Power consumption
8.5 W @ 24 V DC
Type of connection
Screw connection
Type of mounting
Control panel assembly
Voltage supply
18…50 V DC, 18…35 V AC
Input
Attenuation factor
0...99, programmable digital filter
Input current
-22...+22 mA (preset to 4...20 mA)
Input resistance
25 Ω (current input) or 1.5 MΩ (voltage input)
Input signal
-22...+22 mA / -11...+11 V
Input voltage
-11...+11 V
Sensor current
4...20 mA
Output
Last resistor, max.
850 Ω @ 20 mA (current output) / < 500 Ω (voltage output)
Residual ripple (analogue output)
≤ 20 mVss
Transmit function
direct or inverted
Type
Adjustable output for current or voltage
Output current mode
Output current (current mode output)
0 (4)...20 mA
Output (analogue)
Output current
0...22 mA
Transmit function
direct or inverted
Insulation coordination
EMC standards
DIN EN 61326
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV input / power supply
Connection data
Type of connection
Screw connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Classifications
ETIM 6.0
EC000677
ETIM 7.0
EC000677
ETIM 8.0
EC000677
ETIM 9.0
EC000677
ECLASS 9.0
27-14-31-10
ECLASS 9.1
27-21-03-01
ECLASS 10.0
27-14-31-10
ECLASS 11.0
27-14-31-10
ECLASS 12.0
27-14-31-10
ECLASS 13.0
27-14-31-10
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E256486
Version
Input, Current/Voltage, Analogue output, Relay output
Order No.
7940018957
Type
PMX420PLUS DC CE
GTIN (EAN)
4032248594221
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-03-28
Alternative product
2920060000
Height
48.8 mm
Height (inches)
1.921 inch
Width
96.6 mm
Width (inches)
3.803 inch
Length
137 mm
Length (inches)
5.394 inch
Net weight
442.06 g
Storage temperature
-25 °C...70 °C
Operating temperature
0 °C...60 °C
Humidity
0...90 % (no condensation)
REACH SVHC
Lead 7439-92-1
Display range
-9999...9999
Display value
Percentage or real value display
Scaling
Variable
Type
4-digit, red LED, 14.2 mm
Cut-off frequency (-3 dB)
5 Hz
Input/Output
Voltage/current input
Linearity
< 0.05 %
Long-term drift
0.1 % / 10.000 h
Power consumption
8.5 W @ 24 V DC
Type of connection
Screw connection
Type of mounting
Control panel assembly
Voltage supply
18…50 V DC, 18…35 V AC
Attenuation factor
0...99, programmable digital filter
Input current
-22...+22 mA (preset to 4...20 mA)
Input resistance
25 Ω (current input) or 1.5 MΩ (voltage input)
Input signal
-22...+22 mA / -11...+11 V
Input voltage
-11...+11 V
Sensor current
4...20 mA
Last resistor, max.
850 Ω @ 20 mA (current output) / < 500 Ω (voltage output)
Residual ripple (analogue output)
≤ 20 mVss
Transmit function
direct or inverted
Type
Adjustable output for current or voltage
Output current (current mode output)
0 (4)...20 mA
Output current
0...22 mA
Transmit function
direct or inverted
EMC standards
DIN EN 61326
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV input / power supply
Type of connection
Screw connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
ETIM 6.0
EC000677
ETIM 7.0
EC000677
ETIM 8.0
EC000677
ETIM 9.0
EC000677
ECLASS 9.0
27-14-31-10
ECLASS 9.1
27-21-03-01
ECLASS 10.0
27-14-31-10
ECLASS 11.0
27-14-31-10
ECLASS 12.0
27-14-31-10
ECLASS 13.0
27-14-31-10
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E256486
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.