Version Surge protection, 2 MPP's, Surge protection II, Cable gland, PUSH IN connection, 1500 V
Order No. 2756000000
Type VPUM2I2SXFXV2O0TXPX15
GTIN (EAN) 4064675003366
Qty. 1 pc(s).

Dimensions and weights

Depth 91 mm
Depth (inches) 3.583 inch
Height 145 mm
Height (inches) 5.709 inch
Width 168 mm
Width (inches) 6.614 inch
Net weight 869 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -40 °C...85 °C
Humidity 5 - 95% rel. humidity

Enclosure

Connection type string Internal terminal (with cable gland feed-through)
Enclosure attachment Via the four holes under the cover screws
Switch disconnector execution no switch

General data

Protection degree IP67
Standards EN 50539-11

Inputs

Amount of maximum power points 2 MPP
DC Input + & -
Wire connection
Type of connection PUSH IN
Cable entry
Number of cable entries 2
Functional earth connector
Cable entry
Number of cable entries 1
Wire connection
Type of connection PUSH IN
Fuse type Neither fuse cartridge nor holder

Surge protection DC side

Conditions and requirements EN 50539-11
Discharge current In (8/20 µs) 15 kA
Discharge current, max. (8/20 µs) 40 kA
Operating height in the grounded PV system ≤ 4000 m
Operating height in ungrounded PV system ≤ 4000 m
PV system voltage, max. Ucpv 1,500 V
Protection level Up (+/- , -/PE , +/PE) ≤ 4.8 kV
Requirements class Type II
Short-circuit curent ISCPV 11 kA
Standards EN 50539-11
Total discharge current Itotal ( 8/20µs) 50 kA

Important note

Product information The SPD in the box cannot be replaced.

Downloads

Approval/Certificate/Document of Conformity
User Documentation
Catalogues Catalogues in PDF-format

Classifications

ETIM 6.0 EC000941
ETIM 7.0 EC000941
ETIM 8.0 EC000941
ETIM 9.0 EC000941
ECLASS 9.1 27-13-08-05
ECLASS 10.0 27-13-08-05
ECLASS 11.0 27-13-08-05
ECLASS 12.0 27-17-90-90
ECLASS 13.0 27-17-90-90

Tender specification sheets

Long specification Designation 2: VPU PV BOX CG II 5 1500 2M Over voltage protection box for inverters with 2Mpp tracker, used to protect the DC side. Max. String voltage Uoc: 1500 V MPPT1: 1 input, connection via cable gland (4-8mmØ) cable cross section: max. 16mm² MPPT 2 is identical to MPPT 1 Connection of the box in stitch without DC switch 2 surge protection type II Connection of functional earth via cable glands (8-12mmØ) cable cross-section: 16mm² Protection class: IP65 and IP67 Plastic enclosure Dimensions HxWxD:168x145x91 mm According to standard, EN 50539-11: 2013+A1:2014 IEC 61643-31: 2018

Approvals

Approvals CE
ROHS Conform

Related products

Amount of maximum power points:
Requirements class:
Connection type string:
Order No.: 2764140000
Type: VPUM1I1SXFXV1O1TXPX10
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Surge protection, 1 MPP, Surge protection I / II, WM4C, 1000 V
Additional text:
VPU PV BOX WM4 I+II 3 1000 1M
 
Order No.: 2755970000
Type: VPUM1I1SXFXV1O0TXPX10
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Surge protection, 1 MPP, Surge protection I / II, Cable gland, PUSH IN connection, 1000 V
Additional text:
VPU PV BOX CG I+II 3 1000 1M
 
Order No.: 2764110000
Type: VPUM1I1SXFXV2O1TXPX10
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Surge protection, 1 MPP, Surge protection II, WM4C, 1000 V
Additional text:
VPU PV BOX WM4 II 3 1000 1M
 
Order No.: 2755950000
Type: VPUM1I1SXFXV2O0TXPX10
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Surge protection, 1 MPP, Surge protection II, Cable gland, PUSH IN connection, 1000 V
Additional text:
VPU PV BOX CG II 3 1000 1M
 
Order No.: 2764160000
Type: VPUM1I1SXFXV2O1TXPX15
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Surge protection, 1 MPP, Surge protection II, WM4C, 1500 V
Additional text:
VPU PV BOX WM4 II 3 1500 1M
 
Order No.: 2755990000
Type: VPUM1I1SXFXV2O0TXPX15
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Surge protection, 1 MPP, Surge protection II, Cable gland, PUSH IN connection, 1500 V
Additional text:
VPU PV BOX CG II 3 1500 1M
 
Order No.: 2764150000
Type: VPUM2I2SXFXV1O1TXPX10
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Surge protection, 2 MPP's, Surge protection I / II, WM4C, 1000 V
Additional text:
VPU PV BOX WM4 I+II 5 1000 2M
 
Order No.: 2755980000
Type: VPUM2I2SXFXV1O0TXPX10
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Surge protection, 2 MPP's, Surge protection I / II, Cable gland, PUSH IN connection, 1000 V
Additional text:
VPU PV BOX CG I+II 5 1000 2M
 
Order No.: 2764130000
Type: VPUM2I2SXFXV2O1TXPX10
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Surge protection, 2 MPP's, Surge protection II, WM4C, 1000 V
Additional text:
VPU PV BOX WM4 II 5 1000 2M
 
Order No.: 2755960000
Type: VPUM2I2SXFXV2O0TXPX10
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Surge protection, 2 MPP's, Surge protection II, Cable gland, PUSH IN connection, 1000 V
Additional text:
VPU PV BOX CG II 5 1000 2M
 
Order No.: 2764180000
Type: VPUM2I2SXFXV2O1TXPX15
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Surge protection, 2 MPP's, Surge protection II, WM4C, 1500 V
Additional text:
VPU PV BOX WM4 II 5 1500 2M
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts