General ordering data

Version Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
Order No. 2683170000
Type PVN1M1I3SXFXV1O1TXPX10
GTIN (EAN) 4050118700077
Qty. 1 pc(s).
Delivery status Discontinued
Available until 2023-03-31
Alternative product 2890440000

Dimensions and weights

Depth 175 mm
Depth (inches) 6.89 inch
Height 334 mm
Height (inches) 13.15 inch
Width 186 mm
Width (inches) 7.323 inch
Net weight 3,870.261 g

Temperatures

Ambient temperature -40 °C...+50 °C
Humidity 5 - 90 %, no condensation

DC string monitoring

Monitoring function Non monitored

Approvals and norms

Approvals EN 61439-2, IEC 61439-2

Guarantee

Time interval 5 years

Electrical characteristics

Current per Maximum Power Point, max. 45 A
Rated DC current per connection
Current per string, max. 35 A
Rated short-term current resistance
Rated current 56.25 A
Rated DC voltage 1,000 V

Enclosure

Connection type string Plug WM4C
Cover with cover, removeable
Enclosure attachment Via mounting foots
Impact resistance IK08 in accordance with IEC 62208, IK10 in accordance with IEC 62262
Insulating material Polyester glass-fibre reinforced, Polycarbonate
Switch disconnector execution no switch
Type of mounting Wall mounting, 4 screws

General data

Installation location Protected outdoor area (Land and Sea)
Protection degree IP65

Inputs

Amount of maximum power points 1 MPP
DC Input + & -
Wire connection
Type of connection WM4C plug-in connector
Compatible cable crossection EN 50618:2015, TÜV 2 Pfg1169/08.07
Wire cross-section, min. 2.5 mm²
Wire cross-section, max. 6 mm²
Functional earth connector
Cable entry
Number of cable entries 1
Cable diameter, min. 5
Cable diameter, max. 10
Cable glands M 16
Wire connection
Type of connection Screw connection
Flexible, max. H05(07) V-K 25 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 16 mm²
Fuse type Neither fuse cartridge nor holder
Max. number of DC inputs per Maximum Power Point 3 inputs connected in parallel
Surge protection auxiliary contact
Cable entry
Number of cable entries 1
Cable diameter, min. 5
Cable diameter, max. 10
Cable glands M 16
Wire connection
Type of connection Tension clamp connection with actuator
Flexible, max. H05(07) V-K 1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 1.5 mm²

Outputs

DC Output + & -
Wire connection
Type of connection WM4C plug-in connector
Compatible cable crossection TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min. 4 mm²
Wire cross-section, max. 6 mm²
Max. number of DC outputs per Maximum Power Point 3 outputs connected in parallel

Surge protection DC side

Discharge current In (8/20 µs) 20 kA
Discharge current, max. (8/20 µs) 40 kA
Lightning test current Iimp (10/350 µs) 6.25 kA
Maximum continuous operating voltage DC UCPV mode +/-, -/PE, +/PE 1,100 V
PV system voltage, max. Ucpv 1,100 V
Protection level Up (+/- , -/PE , +/PE) ≤ 3.8 kV
Protection level Up (+/-) ≤ 3.8 kV
Protection level Up (+/PE) ≤ 3.8 kV
Protection level Up (-/PE) ≤ 3.8 kV
Requirements class Type I/II
Short-circuit curent ISCPV 11,000 A
Standby power consumption PC < 0.2 W
Total discharge current Itotal ( 8/20µs) 50 kA
Total discharge current Itotal (10/350µs) 12.5 kA

Downloads

Classifications

ETIM 6.0 EC002928
ETIM 7.0 EC002928
ETIM 8.0 EC003857
ETIM 9.0 EC003857
ECLASS 9.0 22-57-92-03
ECLASS 9.1 22-57-02-90
ECLASS 10.0 22-57-02-90
ECLASS 11.0 22-57-02-92
ECLASS 12.0 22-57-02-92
ECLASS 13.0 22-57-02-92

Tender specification sheets

Long specification

Combiner box for inverters with 1 Mpp-tracker,
used to protect the DC side. Max. String voltage Uoc: 1000 V

MPPT1:
Up to 3 inputs, connection via WM4 C connector compatible with cable type TÜV 2 Pfg1169/08.07 / EN 50618:2029
Up to 3 outputs, connection via WM4 C connector compatible with cable type TÜV 2 Pfg1169/08.07 / EN 50618:2029

without DC switch
1 surge protection 1000 V type I + II with remote contact

Connection of the signal contact via cable glands (8-12mmØ) max. cable cross-section: 1.5mm²
Connection of functional earth via cable glands (8-12mmØ) cable cross-section: 16mm²
Protection class: IP65
Plastic enclosure
Dimensions HxWxD: 186x302x175 mm

According to standard, Low-voltage switchgear assemblies -
Part 1: General specifications, (IEC 61439-1:2011), BS EN 61439-2:2025

Approvals

Approvals CE

Related products

Amount of maximum power points:
Requirements class:
Connection type string:
Order No.: 2791920000
Type: PVN DC 2I 1O 1MPP SPD1R WM4 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD1R WM4 1.1kV
 
Order No.: 2866300000
Type: PVN DC 2I 1O 1MPP SPD1R EVO 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2791930000
Type: PVN DC 2I 1O 1MPP SPD1R CG 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD1R CG 1.1kV
 
Order No.: 2791940000
Type: PVN DC 2I 1O 1MPP SPD2R WM4 11
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD2R WM4 1.1kV
 
Order No.: 2866310000
Type: PVN DC 2I 1O1MPP SPD2R EVO 11
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, MC4-Evo 2
 
Order No.: 2791950000
Type: PVN DC 2I 1O 1MPP SPD2R CG 11
Amount of maximum power points: 1 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD2R CG 1.1kV
 
Order No.: 2890440000
Type: PVN DC 3I 3O 1MPP SPD1R WM4 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
 
Order No.: 2890320000
Type: PVN DC 3I 3O 1MPP SPD1R EVO 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2890560000
Type: PVN DC 3I 3O 1MPP SPD1R CG 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
 
Order No.: 2890470000
Type: PVN DC 3I 3O 1MPP SW SPD1R WM4 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C
 
Order No.: 2890350000
Type: PVN DC 3I 3O 1MPP SW SPD1R EVO 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, MC4-Evo 2
 
Order No.: 2890590000
Type: PVN DC 3I 3O 1MPP SW SPD1R CG 11
Amount of maximum power points: 1 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
 
Order No.: 2866340000
Type: PVN DC 2I 1O 2MPP SPD1R WM4 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
 
Order No.: 2866360000
Type: PVN DC 2I 1O 2MPP SPD1R EVO 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2866320000
Type: PVN DC 2I 1O 2MPP SPD1R CG 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
 
Order No.: 2866350000
Type: PVN DC 2I 1O 2MPP SPD2R WM4 11
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
 
Order No.: 2866370000
Type: PVN DC 2I 1O 2MPP SPD2R EVO 11
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, MC4-Evo 2
 
Order No.: 2866330000
Type: PVN DC 2I 1O 2MPP SPD2R CG 11
Amount of maximum power points: 2 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
 
Order No.: 2890450000
Type: PVN DC 3I 3O 2MPP SPD1R WM4 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
 
Order No.: 2890330000
Type: PVN DC 3I 3O 2MPP SPD1R EVO 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2890570000
Type: PVN DC 3I 3O 2MPP SPD1R CG 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
 
Order No.: 2890480000
Type: PVN DC 3I 3O 2MPP SW SPD1R WM4 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C
 
Order No.: 2890360000
Type: PVN DC 3I 3O 2MPP SW SPD1R EVO 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, MC4-Evo 2
 
Order No.: 2890600000
Type: PVN DC 3I 3O 2MPP SW SPD1R CG 11
Amount of maximum power points: 2 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
 
Order No.: 2683190000
Type: PVN1M3I9SXFXV1O1TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD1R WM4 1kV
 
Order No.: 2683220000
Type: PVN1M3I9S0FXV1O1TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD1R WM4 1kV
 
Order No.: 2683130000
Type: PVN1M3I9SXFXV1O0TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD1R CG 1kV
 
Order No.: 2683160000
Type: PVN1M3I9S0FXV1O0TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD1R CG 1kV
 
Order No.: 2683390000
Type: PVN1M3I9SXFXV2O1TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD2R WM4 1kV
 
Order No.: 2683420000
Type: PVN1M3I9S0FXV2O1TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD2R WM4 1kV
 
Order No.: 2683330000
Type: PVN1M3I9SXFXV2O0TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD2R CG 1kV
 
Order No.: 2683360000
Type: PVN1M3I9S0FXV2O0TXPX10
Amount of maximum power points: 3 MPP
Requirements class: Type II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD2R CG 1kV
 
Order No.: 2737600000
Type: PVN DC 2I 1O 4MPP SPD1R WM4 11
Amount of maximum power points: 4 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD1R WM4 1kV
 
Order No.: 2737610000
Type: PVN DC 2I 2O 4MPP SPD1R CG 11
Amount of maximum power points: 4 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD1R CG 1kV
 
Order No.: 2737620000
Type: PVN1M6I4SXFXV1O1TXPX10
Amount of maximum power points: 6 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD1R WM4 1kV
 
Order No.: 2737630000
Type: PVN1M6I4SXFXV1O0TXPX10
Amount of maximum power points: 6 MPP
Requirements class: Type I/II
Connection type string: Internal terminal (with cable gland feed-through)
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD1R CG 1kV
 
Order No.: 8000112516
Type: PVC DC 2I 1O 10MPP SPD1R WM4 11
Amount of maximum power points: 10
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 10 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
 
Order No.: 8000106274
Type: PVC DC 2I 1O 10MPP SPD1R EVO 11
Amount of maximum power points: 10 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 10 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Order No.: 8000107559
Type: PVC DC 2I 2O 10MPP SPD1R EVO 11
Amount of maximum power points: 10 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 10 MPP's, 2 Inputs / 2 Outputs per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Order No.: 8000115469
Type: PVC DC 2I 1O 12MPP SPD1R WM4 11
Amount of maximum power points: 12 MPP
Requirements class: Type I/II
Connection type string: Plug WM4C
Version:
Photovoltaics, Combiner Box, 1100 V, 12 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
 
Order No.: 8000107558
Type: PVC DC 2I 1O 12MPP SPD1R EVO 11
Amount of maximum power points: 12 MPP
Requirements class: Type I/II
Connection type string: Plug MC4-Evo 2
Version:
Photovoltaics, Combiner Box, 1100 V, 12 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts