Dimensions and weights
Depth
48 mm
Depth (inches)
1.89 inch
Height
96 mm
Height (inches)
3.78 inch
Width
96 mm
Width (inches)
3.78 inch
Net weight
250 g
Temperatures
Storage temperature
-25 °C...70 °C
Operating temperature
-10 °C...55 °C
Humidity at operating temperature
15…95 % RH
Measuring current input
Current-measuring channels
3
Distortion factor THD-I in %
No
Measuring accuracy for current
1 %
Rated current
1 / 5 A
Residual current measuring
No
Measuring voltage input
Distortion factor THD-U in %
No
Four-wire system
Yes
Measurement range, voltage L-L, AC
476 V
Measurement range, voltage L-N, AC
275 V
Measuring accuracy for voltage
1 %
Quadrants
4
Three-wire system
No
Inputs/outputs
Number of digital outputs
2
Number of pulse outputs
2
Temperature input
No
Measurement data recording
Memory; minimum and maximum values
Yes
Integrated logic
No
Technical data
Pollution severity
2
Protection degree
Enclosure: IP20, IP40
Rated current
1 / 5 A
Version
Power measurement/display for 1-, 3-phase mains
Standards
DIN EN 61326-1, DIN EN 61000-4-2, DIN EN 61000-4-3, DIN EN 61000-4-4, DIN EN 61000-4-5, DIN EN 61000-4-6, DIN EN 61000-4-8, EN 61000-4-11, EN 55011, IEC 61010-1, IEC 61010-2-030
Measurement range, voltage L-N, AC
275 V
Measurement range, voltage L-L, AC
476 V
Surge voltage category
300 V CAT III
Voltage supply
196...275 V AC
Supply voltage
230 V
Three-wire system
No
Four-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
3 kHz
Continuous measurements
No
Measurement result per second
1 ms
Effective value from the period (50/60 Hz)
1 / 1
Residual current measuring
No
Current-measuring channels
3
Measuring accuracy for voltage
1 %
Measuring accuracy for current
1 %
Measurement accuracy for active energy (kWh, .../5 A)
DIN EN 61326-1, DIN EN 61000-4-2, DIN EN 61000-4-3, DIN EN 61000-4-4, DIN EN 61000-4-5, DIN EN 61000-4-6, DIN EN 61000-4-8, EN 61000-4-11, EN 55011, IEC 61010-1, IEC 61010-2-030
Measurement range, voltage L-N, AC
275 V
Measurement range, voltage L-L, AC
476 V
Surge voltage category
300 V CAT III
Voltage supply
196...275 V AC
Supply voltage
230 V
Three-wire system
No
Four-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
3 kHz
Continuous measurements
No
Measurement result per second
1 ms
Effective value from the period (50/60 Hz)
1 / 1
Residual current measuring
No
Current-measuring channels
3
Measuring accuracy for voltage
1 %
Measuring accuracy for current
1 %
Measurement accuracy for active energy (kWh, .../5 A)
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.