General ordering data

Version Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
Order No. 1989930000
Type ADT 2.5 2C W/O DTLV
GTIN (EAN) 4050118374483
Qty. 50 pc(s).

Dimensions and weights

Depth 36.5 mm
Depth (inches) 1.437 inch
Depth including DIN rail 37 mm
Height 77.5 mm
Height (inches) 3.051 inch
Width 5.1 mm
Width (inches) 0.201 inch
Net weight 9.117 g

Temperatures

Storage temperature -25 °C...55 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C

Material data

Material Wemid
Colour dark beige
Colour of operational elements orange
UL 94 flammability rating V-0

System specifications

End cover plate required Yes
Number of potentials
Number of levels
Number of clamping points per level
Number of potentials per tier
Levels cross-connected internally No
PE connection No
Rail TS 35
N-function No
PE function No
PEN function No

Additional technical data

Installation advice Rail
Open sides right
Snap-on No
Type of fixing Snap-on
Type of mounting TS 35
With snap-in pegs No

CSA rating data

Certificate No. (CSA) 200039-70089609
Current size B (CSA) 20 A
Current size C (CSA) 20 A
Current size D (CSA) 5 A
Voltage size B (CSA) 300 V
Voltage size C (CSA) 300 V
Voltage size D (CSA) 600 V
Wire cross section max. (CSA) 12 AWG
Wire cross section min. (CSA) 28 AWG

Conductors for clamping (rated connection)

Blade size 0.6 x 3.5 mm
Clamping range, max. 4 mm²
Clamping range, min. 0.14 mm²
Connection cross-section, stranded, max. 4 mm²
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A3
Number of connections
Stripping length 10 mm
Tube length for twin wire-end ferrule
Cross-section for conductor connection
min. 0.5 mm²
max. 0.75 mm²
Tube length
min. 8 mm
max. 12 mm
Tube length for wire-end ferrule with plastic collar DIN 46228/4
Tube length
min. 8 mm
max. 6 mm
Cross-section for conductor connection
min. 0.34 mm²
max. 0.14 mm²
Tube length
min. 12 mm
max. 6 mm
Cross-section for conductor connection
min. 1 mm²
max. 0.5 mm²
Tube length
min. 12 mm
max. 8 mm
Cross-section for conductor connection
min. 2.5 mm²
max. 1.5 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1
Cross-section for conductor connection
nominal 0.25 mm²
Tube length
nominal 5 mm
Cross-section for conductor connection
min. 0.5 mm²
max. 1 mm²
Tube length
min. 6 mm
max. 10 mm
Cross-section for conductor connection
min. 1.5 mm²
max. 4 mm²
Tube length
min. 7 mm
max. 12 mm
Twin wire-end ferrules, max. 0.75 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection PUSH IN
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 28
Wire connection cross section, finely stranded, max. 4 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, solid core, max. 2.5 mm²
Wire connection cross-section, solid core, min. 0.5 mm²

Disconnect terminals

Cross-disconnect without
Integral test socket Yes

General

Installation advice Rail
Rail TS 35
Standards IEC 60947-7-1
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 28

Rating data

Rated cross-section 2.5 mm²
Rated voltage 500 V
Rated DC voltage 500 V
Rated current 20 A
Current at maximum wires 20 A
Standards IEC 60947-7-1
Volume resistance according to IEC 60947-7-x 1.33 mΩ
Rated impulse withstand voltage 6 kV
Power loss in accordance with IEC 60947-7-x 0.77 W
Pollution severity 3
Surge voltage category III

UL rating data

Certificate No. (cURus) E60693
Conductor size Factory wiring max. (cURus) 12 AWG
Conductor size Factory wiring min. (cURus) 28 AWG
Conductor size Field wiring max. (cURus) 12 AWG
Conductor size Field wiring min. (cURus) 28 AWG
Current size B (cURus) 20 A
Current size C (cURus) 20 A
Current size D (cURus) 5 A
Voltage size B (cURus) 300 V
Voltage size C (cURus) 300 V
Voltage size D (cURus) 600 V

Downloads

Classifications

ETIM 6.0 EC000902
ETIM 7.0 EC000902
ETIM 8.0 EC000902
ETIM 9.0 EC000902
ECLASS 9.0 27-14-11-26
ECLASS 9.1 27-14-11-26
ECLASS 10.0 27-14-11-26
ECLASS 11.0 27-14-11-26
ECLASS 12.0 27-14-11-26
ECLASS 13.0 27-25-01-09

Approvals

Approvals CE CSA CURUS DETNORVER KEMAKEUR UKCA
ROHS Conform
UL File Number Search UL Website
Certificate No. (cURus) E60693

Related products

Order No.: 1989900000
Type: A2C 2.5 /DT/FS
Version:
Feed-through terminal, PUSH IN, 2.5 mm², 800 V, 24 A, dark beige
 
Order No.: 1989910000
Type: A2C 2.5 /DT/FS BL
Version:
Feed-through terminal, PUSH IN, 2.5 mm², 800 V, 24 A, blue
 
Order No.: 1989920000
Type: A2C 2.5 /DT/FS OR
Version:
Feed-through terminal, PUSH IN, 2.5 mm², 800 V, 24 A, orange
 
Order No.: 1989890000
Type: A2C 2.5 PE/DT/FS
Version:
PE terminal, PUSH IN, 2.5 mm², Green/yellow
 
Order No.: 1989800000
Type: ADT 2.5 2C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
 
Order No.: 1989810000
Type: ADT 2.5 2C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, blue
 
Order No.: 1989820000
Type: ADT 2.5 2C OR
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, orange
 
Order No.: 2430040000
Type: ADT 2.5 2C W/O DTLV BL
Version:
PUSH IN, 2.5 mm², 500 V, 20 A, blue
 
Order No.: 1989830000
Type: ADT 2.5 3C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
 
Order No.: 1989840000
Type: ADT 2.5 3C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, blue
 
Order No.: 1989850000
Type: ADT 2.5 3C OR
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, orange
 
Order No.: 1989940000
Type: ADT 2.5 3C W/O DTLV
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
 
Order No.: 1989860000
Type: ADT 2.5 4C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
 
Order No.: 1989870000
Type: ADT 2.5 4C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, blue
 
Order No.: 1989880000
Type: ADT 2.5 4C OR
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, orange
 
Order No.: 1989950000
Type: ADT 2.5 4C W/O DTLV
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, dark beige
 
Order No.: 2898660000
Type: ALDT 2.5 2C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, dark beige
 
Order No.: 2898670000
Type: ALDT 2.5 2C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, blue
 
Order No.: 2898680000
Type: ALDT 2.5 2C W/O DTLV
Version:
Basic terminal for component plug, 2
 
Order No.: 2898690000
Type: ALDT 2.5 2C W/O DTLV BL
Version:
Basic terminal for component plug, 2
 
Order No.: 2898700000
Type: ALDT 2.5 3C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, dark beige
 
Order No.: 2898710000
Type: ALDT 2.5 3C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, blue
 
Order No.: 2898720000
Type: ALDT 2.5 4C
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, dark beige
 
Order No.: 2898730000
Type: ALDT 2.5 4C BL
Version:
Test-disconnect terminal, PUSH IN, 2.5 mm², 500 V, 20 A, Pivoting, Cross-disconnect: without, Integral test socket: Yes, TS 35, blue
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts