Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
PLC Interfaces and Migration Solutions
Cord sets, Patchcords and Cables
Service Interfaces
Distribution Boxes
Solutions for PLCs
Solutions for Honeywell C300
Solutions for Yokogawa
Interfaces for general applications
Interfaces with insulation for general solutions
Solutions for Smart Metering
Pre-assembled cables for general applications
Migrations between PLCs
Card holders
Interfaces with relays
Pre-cabling system for TERMSERIES
Relays 1 CO contact
Relays 1 compact CO contact
Relays 2 CO contacts
General ordering data
Version
Interface, RSM, Screw connection
Order No.
1448930000
Type
RSM-8 24V+ 2CO S
GTIN (EAN)
4050118253436
Qty.
1 pc(s).
Dimensions and weights
Depth
71 mm
Depth (inches)
2.795 inch
Height
109 mm
Height (inches)
4.291 inch
Width
149 mm
Width (inches)
5.866 inch
Net weight
440.408 g
Temperatures
Storage temperature
-40...60 °C
Operating temperature
-25...50 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
71d9bdc4-a0b5-4af0-93bd-2ad4e523fb14
General data
LED status display per relay
green
LED status of the supply voltage
yellow
Connection data
Connection (field side)
LL2N 5.08 mm
Connection on control side
LP 5.08 + plug-in connector in acc. with IEC60603-13 / DIN41651, 10-pin, LL 5.08 mm
Rating data
Mechanical service life
30 x 106 switching cycles
Ratings data input
Input voltage
24 V DC ± 10%
Input current
16.7 mA
Ratings data output
Relay type
RCL
Type of output
Potential-free contact
Contact material
AgNi 90/10
Rated voltage
≤ 250 V AC
Max. AC continuous current
5 A
Minimum contact current
0.1 A
Minimum contact voltage
5 V
Insulation coordination (EN50178)
Pollution severity level
2
Pulse voltage test (1,2/50μs)
6 kV
Insulation test voltage AC
1.2 kV
Insulation coordinates (EN50178)
Rated input insulation voltage
< 50 V AC
Rated output insulation voltage
250 V AC
Overvoltage category input/output
III
Overvoltage category output/output
III
Pollution severity level
2
Pulse voltage test (1,2/50μs)
6 kV
Insulation test voltage AC
1.2 kV
Clearance input/output
≥ 5.5 mm
Connection field
Clamping range, max.
6 mm²
Clamping range, min.
0.5 mm²
Flexible with sleeve, max.
2.5 mm²
Flexible with sleeve, min.
0.5 mm²
Flexible, max. H05(07) V-K
4 mm²
Flexible, min. H05(07) V-K
0.5 mm²
Max. wire cross-section, AWG
AWG 12
Min. wire cross-section, AWG
AWG 26
Sleeve with plastic collar, max.
2.5 mm²
Solid, max. H05(07) V-U
6 mm²
Solid, min. H05(07) V-U
0.5 mm²
Stripping length
6 mm
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Type of connection
Screw connection
Downloads
Approval/Certificate/Document of Conformity
Product Change Notification
Catalogues
Catalogues in PDF-format
Brochures
Classifications
ETIM 6.0
EC002780
ETIM 7.0
EC002780
ETIM 8.0
EC002780
ETIM 9.0
EC002780
ECLASS 9.0
27-14-11-52
ECLASS 9.1
27-24-22-16
ECLASS 10.0
27-14-11-52
ECLASS 11.0
27-14-11-52
ECLASS 12.0
27-14-11-52
ECLASS 13.0
27-14-11-52
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UR)
E141197
Order No.:
1448610000
Type:
RSM-4 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448630000
Type:
RSM-4 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448620000
Type:
RSM-4 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448640000
Type:
RSM-4 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448650000
Type:
RSM-4 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448680000
Type:
RSM-4 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448670000
Type:
RSM-4 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448690000
Type:
RSM-4 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448820000
Type:
RSM-4I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448830000
Type:
RSM-4I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448740000
Type:
RSM-4 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448770000
Type:
RSM-4 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448700000
Type:
RSM-4 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448720000
Type:
RSM-4 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448710000
Type:
RSM-4 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448730000
Type:
RSM-4 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448780000
Type:
RSM-4 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448790000
Type:
RSM-4 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448800000
Type:
RSM-4 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448810000
Type:
RSM-4 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448890000
Type:
RSM-8 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448910000
Type:
RSM-8 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448900000
Type:
RSM-8 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448920000
Type:
RSM-8 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448950000
Type:
RSM-8 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448940000
Type:
RSM-8 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448970000
Type:
RSM-8 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449100000
Type:
RSM-8I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449110000
Type:
RSM-8I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449030000
Type:
RSM-8 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449040000
Type:
RSM-8 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448980000
Type:
RSM-8 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449010000
Type:
RSM-8 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448990000
Type:
RSM-8 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449020000
Type:
RSM-8 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449050000
Type:
RSM-8 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449070000
Type:
RSM-8 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449080000
Type:
RSM-8 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449090000
Type:
RSM-8 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449170000
Type:
RSM-16 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449190000
Type:
RSM-16 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449180000
Type:
RSM-16 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449200000
Type:
RSM-16 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449210000
Type:
RSM-16 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449230000
Type:
RSM-16 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449220000
Type:
RSM-16 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449250000
Type:
RSM-16 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449380000
Type:
RSM-16I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449390000
Type:
RSM-16I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449310000
Type:
RSM-16 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449320000
Type:
RSM-16 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449270000
Type:
RSM-16 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449290000
Type:
RSM-16 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449280000
Type:
RSM-16 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449300000
Type:
RSM-16 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449330000
Type:
RSM-16 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449340000
Type:
RSM-16 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449350000
Type:
RSM-16 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449370000
Type:
RSM-16 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Version
Interface, RSM, Screw connection
Order No.
1448930000
Type
RSM-8 24V+ 2CO S
GTIN (EAN)
4050118253436
Qty.
1 pc(s).
Depth
71 mm
Depth (inches)
2.795 inch
Height
109 mm
Height (inches)
4.291 inch
Width
149 mm
Width (inches)
5.866 inch
Net weight
440.408 g
Storage temperature
-40...60 °C
Operating temperature
-25...50 °C
REACH SVHC
Lead 7439-92-1
SCIP
71d9bdc4-a0b5-4af0-93bd-2ad4e523fb14
LED status display per relay
green
LED status of the supply voltage
yellow
Connection (field side)
LL2N 5.08 mm
Connection on control side
LP 5.08 + plug-in connector in acc. with IEC60603-13 / DIN41651, 10-pin, LL 5.08 mm
Mechanical service life
30 x 106 switching cycles
Input voltage
24 V DC ± 10%
Input current
16.7 mA
Relay type
RCL
Type of output
Potential-free contact
Contact material
AgNi 90/10
Rated voltage
≤ 250 V AC
Max. AC continuous current
5 A
Minimum contact current
0.1 A
Minimum contact voltage
5 V
Pollution severity level
2
Pulse voltage test (1,2/50μs)
6 kV
Insulation test voltage AC
1.2 kV
Rated input insulation voltage
< 50 V AC
Rated output insulation voltage
250 V AC
Overvoltage category input/output
III
Overvoltage category output/output
III
Pollution severity level
2
Pulse voltage test (1,2/50μs)
6 kV
Insulation test voltage AC
1.2 kV
Clearance input/output
≥ 5.5 mm
Clamping range, max.
6 mm²
Clamping range, min.
0.5 mm²
Flexible with sleeve, max.
2.5 mm²
Flexible with sleeve, min.
0.5 mm²
Flexible, max. H05(07) V-K
4 mm²
Flexible, min. H05(07) V-K
0.5 mm²
Max. wire cross-section, AWG
AWG 12
Min. wire cross-section, AWG
AWG 26
Sleeve with plastic collar, max.
2.5 mm²
Solid, max. H05(07) V-U
6 mm²
Solid, min. H05(07) V-U
0.5 mm²
Stripping length
6 mm
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Type of connection
Screw connection
ETIM 6.0
EC002780
ETIM 7.0
EC002780
ETIM 8.0
EC002780
ETIM 9.0
EC002780
ECLASS 9.0
27-14-11-52
ECLASS 9.1
27-24-22-16
ECLASS 10.0
27-14-11-52
ECLASS 11.0
27-14-11-52
ECLASS 12.0
27-14-11-52
ECLASS 13.0
27-14-11-52
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UR)
E141197
Order No.:
1448610000
Type:
RSM-4 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448630000
Type:
RSM-4 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448620000
Type:
RSM-4 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448640000
Type:
RSM-4 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448650000
Type:
RSM-4 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448680000
Type:
RSM-4 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448670000
Type:
RSM-4 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448690000
Type:
RSM-4 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448820000
Type:
RSM-4I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448830000
Type:
RSM-4I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448740000
Type:
RSM-4 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448770000
Type:
RSM-4 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448700000
Type:
RSM-4 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448720000
Type:
RSM-4 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448710000
Type:
RSM-4 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448730000
Type:
RSM-4 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448780000
Type:
RSM-4 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448790000
Type:
RSM-4 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448800000
Type:
RSM-4 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448810000
Type:
RSM-4 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448890000
Type:
RSM-8 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448910000
Type:
RSM-8 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448900000
Type:
RSM-8 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448920000
Type:
RSM-8 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448950000
Type:
RSM-8 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448940000
Type:
RSM-8 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1448970000
Type:
RSM-8 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449100000
Type:
RSM-8I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449110000
Type:
RSM-8I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449030000
Type:
RSM-8 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449040000
Type:
RSM-8 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448980000
Type:
RSM-8 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449010000
Type:
RSM-8 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1448990000
Type:
RSM-8 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449020000
Type:
RSM-8 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449050000
Type:
RSM-8 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449070000
Type:
RSM-8 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449080000
Type:
RSM-8 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449090000
Type:
RSM-8 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449170000
Type:
RSM-16 12V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449190000
Type:
RSM-16 12V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449180000
Type:
RSM-16 12V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449200000
Type:
RSM-16 12V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449210000
Type:
RSM-16 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449230000
Type:
RSM-16 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449220000
Type:
RSM-16 24V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449250000
Type:
RSM-16 24V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449380000
Type:
RSM-16I 24V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449390000
Type:
RSM-16I 24V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449310000
Type:
RSM-16 24VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449320000
Type:
RSM-16 24VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449270000
Type:
RSM-16 48V+ 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449290000
Type:
RSM-16 48V+ 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449280000
Type:
RSM-16 48V- 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449300000
Type:
RSM-16 48V- 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449330000
Type:
RSM-16 115VAC/DC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449340000
Type:
RSM-16 115VAC/DC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
Order No.:
1449350000
Type:
RSM-16 230VAC 2CO S
Version:
Interface, RSM, Screw connection
Order No.:
1449370000
Type:
RSM-16 230VAC 2CO Z
Version:
Interface, RSM, Tension-clamp connection
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.