FP BOX 10P 4XVG
         

Icon
 

General ordering data

Version FieldPower® power distribution box, 3-phase AC, IP65, in complete state, glass-fibre reinforced polycarbonate, PUSH IN, Insulation displacement connection (IDC)
Order No. 1002900000
Type FP BOX 10P 4XVG
GTIN (EAN) 4032248697038
Qty. 1 pc(s).

Dimensions and weights

Depth 67 mm
Depth (inches) 2.638 inch
Height 181 mm
Height (inches) 7.126 inch
Width 223 mm
Width (inches) 8.78 inch
Net weight 1,500 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -40 °C...55 °C

Environmental Product Compliance

REACH SVHC Potassium perfluorobutane sulfonate 29420-49-3
SCIP 5f19cd84-8946-4797-9386-3ac323b95c10

Cable gland

Cable gland clamping area, max. 12 mm
Cable gland clamping area, min. 6 mm
Cable gland material Polyamide 6
Number of cable glands

Clamping capacity

Connection data - contact element power bus
Wire connection method Insulation displacement connection (IDC)
Blade size of operating tool 0.6 x 3.5 mm
Number of poles 5
Conductor connection cross-section, solid, max. 6 mm²
Conductor connection cross-section, solid, min. 1.5 mm²
Conductor connection cross-section, stranded, max. 6 mm²
Conductor connection cross-section, stranded, min. 2.5 mm²
Conductor connection cross-section, finely stranded, max. 6 mm²
Conductor connection cross-section, finely stranded, min. 2.5 mm²
Conductor connection cross-section, finest stranded, max. 6 mm²
Conductor connection cross-section, finest stranded, min. 2.5 mm²
Connection data - contact element Branch / Feed-in
Wire connection method PUSH IN
Blade size of operating tool 0.6 x 3.5 mm
Stripping length 14 mm
Number of poles 5
Conductor connection cross-section, solid, max. 6 mm²
Conductor connection cross-section, solid, min. 0.5 mm²
Conductor connection cross-section, stranded, max. 6 mm²
Conductor connection cross-section, stranded, min. 0.5 mm²
Conductor connection cross-section, finely stranded, max. 10 mm²
Conductor connection cross-section, finely stranded, min. 0.5 mm²
Conductor connection cross-section, finest stranded, max. 6 mm²
Conductor connection cross-section, finest stranded, min. 0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule 12 mm with plastic collar
Standard DIN 46228/1
Cross-section, min. 0.5 mm²
Cross-section, max. 6 mm²
Type of wire end ferrule 12 mm with plastic collar
Standard DIN 46228/4
Cross-section, min. 0.5 mm²
Cross-section, max. 6 mm²
Type of wire end ferrule 8 mm with plastic collar
Standard DIN 46228/1
Cross-section, min. 0.5 mm²
Cross-section, max. 6 mm²
Type of wire end ferrule 8 mm with plastic collar
Standard DIN 46228/4
Cross-section, min. 0.5 mm²
Cross-section, max. 6 mm²
Type of wire end ferrule Twin wire-end ferrules
Cross-section, min. 0.5 mm²
Cross-section, max. 6 mm²

General data

Insulating material Polycarbonate
Enclosure material glass-fibre reinforced polycarbonate
Silicone No
Colour black
Protection degree IP65, in complete state
UL 94 flammability rating 5VA
Torque for lid screws 2 Nm
Lid attachment TX20 screws
Type of mounting Screw mounting, Fixing lugs
Installation advice Lid screws included
With cable gland Yes
Can be coded Yes, Coded on PE
Voltage type 3-phase AC
Number of poles 2 x 5
Number of connections / pole
Wire connection method PUSH IN, Insulation displacement connection (IDC)

Rated data acc. to IEC

Rated data acc. to IEC for contact element
Voltage type AC, DC
Standard IEC 60947-7-1, IEC 60947-7-2
Rated voltage 800 V
Rated impulse withstand voltage 8 kV
Rated current (3 loaded poles) 41 A
Rated current (4 loaded poles) 25 A
Rated data acc. to IEC for plug-in connector
Voltage type AC
Number of phases 3
Standard IEC 60947-7-1, IEC 60947-7-2, IEC 61984
Rated voltage 690 V
Rated impulse withstand voltage 8 kV
Rated current (3 loaded poles) 32 A
Rated current (4 loaded poles) 25 A

Rated data acc. to UL

Rated data acc. to UL for contact element
Standard UL 1059
Note for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max. AWG 10
Conductor connection cross-section, AWG, min. AWG 14
Rated voltage 600 V
Rated current 30 A
Rated data acc. to UL for plug-in connector
Standard UL 1059
Note for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max. AWG 12
Conductor connection cross-section, AWG, min. AWG 16
Rated voltage 600 V
Rated current 20 A
Standards not UL approved

Downloads

Classifications

ETIM 6.0 EC000214
ETIM 7.0 EC000214
ETIM 8.0 EC000214
ETIM 9.0 EC000214
ECLASS 9.0 27-14-24-09
ECLASS 9.1 27-14-24-09
ECLASS 10.0 27-14-24-09
ECLASS 11.0 27-14-24-09
ECLASS 12.0 27-14-24-09
ECLASS 13.0 27-14-24-09

Approvals

ROHS Conform

Related products

Order No.: 1957580000
Type: FP BOX
Version:
FieldPower® power distribution box, AC, IP65, in complete state, glass-fibre reinforced polycarbonate, Insulation displacement connection (IDC), PUSH IN
 
Order No.: 1957590000
Type: FP BOX 10P
Version:
FieldPower® power distribution box, IP65, glass-fibre reinforced polycarbonate
 
Order No.: 1440920000
Type: FP BOX DC
Version:
FieldPower® power distribution box, DC, IP65, in complete state, glass-fibre reinforced polycarbonate, PUSH IN, Insulation displacement connection (IDC)
 
Order No.: 1059320000
Type: FP BOX SET D9
Version:
FieldPower® power distribution box, IP65, in complete state, glass-fibre reinforced polycarbonate, PUSH IN, Insulation displacement connection (IDC)
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts