Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
PLC Interfaces and Migration Solutions
Cord sets, Patchcords and Cables
Service Interfaces
Distribution Boxes
Universal range
Application range
Terminal blocks for the direct lettering
Accessories
SNAP IN technology
PUSH IN technology
Tension clamp technology
Clamping yoke technology
Stud technology
W-Series
SAK-Series
TS 35
TS 32
TS 32 / TS 35 EN combination foot:
TS 15
Multi-pole terminal strips
Direct Mounting
Feed-through terminal blocks
Fuse terminal blocks
Modular PE terminal blocks
Modular terminal blocks with electronic components
Modular test-disconnect terminal blocks
Thermocouple terminal blocks
terminal blocks with miscellaneous connection
terminal blocks with spring-loaded cable clamp
1-tier
2-tier
4 mm²
6 mm²
10 mm²
General ordering data
Version
Test-disconnect terminal, Screw connection, 10 mm², 500 V, 47 A, sliding, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
Order No.
0134120000
Type
SAKA 10
GTIN (EAN)
4008190083380
Qty.
25 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-12-31
Alternative product
2710090000
Dimensions and weights
Depth
55.5 mm
Depth (inches)
2.185 inch
Height
82 mm
Height (inches)
3.228 inch
Width
12 mm
Width (inches)
0.472 inch
Net weight
63 g
Temperatures
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-60 °C
Continuous operating temp., max.
130 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
999cd67e-471e-4085-8dba-1342fcea86de
Material data
Material
KrG
Colour
medium yellow
UL 94 flammability rating
V-0, 5VA
System specifications
Version
Screw connection, Spacer, With sockets, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
No
Rail
TS 32
N-function
No
PE function
No
PEN function
No
Additional technical data
Explosion-tested version
No
Installation advice
Direct mounting
Number of similar terminals
1
Open sides
right
Type of mounting
Snap-on
CSA rating data
Certificate No. (CSA)
12400-189
Current size B (CSA)
35 A
Current size C (CSA)
35 A
Current size D (CSA)
5 A
Voltage size B (CSA)
600 V
Voltage size C (CSA)
600 V
Voltage size D (CSA)
600 V
Wire cross section max. (CSA)
8 AWG
Wire cross section min. (CSA)
18 AWG
Conductors for clamping (rated connection)
Blade size
1.0 x 5.5 mm
Clamping range, max.
10 mm²
Clamping range, min.
0.5 mm²
Clamping screw
M 4
Connection cross-section, stranded, max.
10 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection direction
on side
Gauge to IEC 60947-1
B6
Number of connections
2
Stripping length
12 mm
Tightening torque, max.
2.4 Nm
Tightening torque, min.
1.2 Nm
Torque level with DMS electric screwdriver
4
Type of connection
Screw connection
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
Wire connection cross section, finely stranded, max.
10 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
1.5 mm²
Wire connection cross-section, solid core, max.
16 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
Disconnect terminals
Cross-disconnect
without
Integral test socket
Yes
Slitting
sliding
General
Installation advice
Direct mounting
Rail
TS 32
Standards
IEC 60947-7-1
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
Rating data
Rated cross-section
10 mm²
Rated voltage
500 V
Rated DC voltage
500 V
Rated current
47 A
Current at maximum wires
47 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
0.56 mΩ
Rated impulse withstand voltage
6 kV
Power loss in accordance with IEC 60947-7-x
1.82 W
Pollution severity
3
Classifications
ETIM 6.0
EC000902
ETIM 7.0
EC000902
ETIM 8.0
EC000902
ETIM 9.0
EC000902
ECLASS 9.0
27-14-11-26
ECLASS 9.1
27-14-11-26
ECLASS 10.0
27-14-11-26
ECLASS 11.0
27-14-11-26
ECLASS 12.0
27-14-11-26
ECLASS 13.0
27-25-01-09
Order No.:
0324120000
Type:
SAKC 10 2STB
Version:
Test-disconnect terminal, Screw connection, 10 mm², 500 V, 26 A, pluggable, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
Order No.:
0324020000
Type:
SAKC 10 STB/RE
Version:
Test-disconnect terminal, Screw connection, 10 mm², 400 V, 26 A, pluggable, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
Version
Test-disconnect terminal, Screw connection, 10 mm², 500 V, 47 A, sliding, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
Order No.
0134120000
Type
SAKA 10
GTIN (EAN)
4008190083380
Qty.
25 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-12-31
Alternative product
2710090000
Depth
55.5 mm
Depth (inches)
2.185 inch
Height
82 mm
Height (inches)
3.228 inch
Width
12 mm
Width (inches)
0.472 inch
Net weight
63 g
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-60 °C
Continuous operating temp., max.
130 °C
REACH SVHC
Lead 7439-92-1
SCIP
999cd67e-471e-4085-8dba-1342fcea86de
Material
KrG
Colour
medium yellow
UL 94 flammability rating
V-0, 5VA
Version
Screw connection, Spacer, With sockets, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
No
Rail
TS 32
N-function
No
PE function
No
PEN function
No
Explosion-tested version
No
Installation advice
Direct mounting
Number of similar terminals
1
Open sides
right
Type of mounting
Snap-on
Certificate No. (CSA)
12400-189
Current size B (CSA)
35 A
Current size C (CSA)
35 A
Current size D (CSA)
5 A
Voltage size B (CSA)
600 V
Voltage size C (CSA)
600 V
Voltage size D (CSA)
600 V
Wire cross section max. (CSA)
8 AWG
Wire cross section min. (CSA)
18 AWG
Blade size
1.0 x 5.5 mm
Clamping range, max.
10 mm²
Clamping range, min.
0.5 mm²
Clamping screw
M 4
Connection cross-section, stranded, max.
10 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection direction
on side
Gauge to IEC 60947-1
B6
Number of connections
2
Stripping length
12 mm
Tightening torque, max.
2.4 Nm
Tightening torque, min.
1.2 Nm
Torque level with DMS electric screwdriver
4
Type of connection
Screw connection
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
Wire connection cross section, finely stranded, max.
10 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
10 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
1.5 mm²
Wire connection cross-section, solid core, max.
16 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
Cross-disconnect
without
Integral test socket
Yes
Slitting
sliding
Installation advice
Direct mounting
Rail
TS 32
Standards
IEC 60947-7-1
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
Rated cross-section
10 mm²
Rated voltage
500 V
Rated DC voltage
500 V
Rated current
47 A
Current at maximum wires
47 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
0.56 mΩ
Rated impulse withstand voltage
6 kV
Power loss in accordance with IEC 60947-7-x
1.82 W
Pollution severity
3
ETIM 6.0
EC000902
ETIM 7.0
EC000902
ETIM 8.0
EC000902
ETIM 9.0
EC000902
ECLASS 9.0
27-14-11-26
ECLASS 9.1
27-14-11-26
ECLASS 10.0
27-14-11-26
ECLASS 11.0
27-14-11-26
ECLASS 12.0
27-14-11-26
ECLASS 13.0
27-25-01-09
Order No.:
0324120000
Type:
SAKC 10 2STB
Version:
Test-disconnect terminal, Screw connection, 10 mm², 500 V, 26 A, pluggable, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
Order No.:
0324020000
Type:
SAKC 10 STB/RE
Version:
Test-disconnect terminal, Screw connection, 10 mm², 400 V, 26 A, pluggable, Cross-disconnect: without, Integral test socket: Yes, TS 32, medium yellow
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.