Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
Pluggable arresters for VSPC
Base elements for VSPC
Supply and alert unit for VSPC R arresters
Accessories for the VSPC series
2-level protection for analogue and binary signals
Combi-module protects 24V supply voltage and a current loop
Surge protection for Uk0 /S0 interfaces (telecomm.)
Surge protection for data signals
Surge protection with components such as varistors, gas arresters or suppressor diodes
Surge protection for binary signals and EX ia signals
Surge protection for current loops and EX ia signals
Three-wire and four-wire measuring bridges
General ordering data
Version
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.
8953650000
Type
VSPC 3/4WIRE 5VDC EX
GTIN (EAN)
4032248745807
Qty.
1 pc(s).
Dimensions and weights
Depth
69 mm
Depth (inches)
2.717 inch
Height
90 mm
Height (inches)
3.543 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
53 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
Probability of failure
SIL in compliance with IEC 61508
3
MTTF
2,655 a
SFF
95.33 %
λges
43
PFH in 1*10-9 per hour
7
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
Protection Ex - Data
ATEX - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX)
KEMA10ATEX0148X
IECEx - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI
3 W
Input voltage, max. Ui
6 V
Internal capacity, max. CI
<4 nF
Internal inductance, max. LI
0 µH
Temperature class T4/135°C (-40°C ... +85°C) li
350 mA
Temperature class T5/100°C (-40 ° C ... +75°C) li
250 mA
Temperature class T6/85 °C (-40 °C ... +60°C) li
250 mA
CSA protection data
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
6 V
Internal capacity, max. CI
4 nF
Internal inductance, max. LI
0 µH
General data
Colour
Light Blue
Design
Terminal, miscellaneous
Optical function display
No
Protection degree
IP20
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
without warning function / function indicator
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Capacitance
2.3 pF
Dielectric strength at FG against PE
≥ 500 V
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Input voltage, max. Ui
6 V
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
6.4 V
Number of poles
2
Overload - failure mode
Modus 2
Protection level UP (typ.)
<800 V
Protection level on output side Wire-PE 1kV/µs, typically
250 V
Protection level on output side Wire-wire 1 kV/µs, typically
35 V
Protection level on output side Wire-wire 8/20 µs, typically
35 V
Protection level, UP GND - PE
450 V
Protection level, UP wire - PE
10 V
Protection level, UP wire - wire
20 V
Pulse-reset capacity
≤ 20 ms
Rated current IN
300 mA
Rated voltage (DC)
3 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
750 KHz
Signalling contact
No
Standards
IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
0.20 Ω
Connection data
Type of connection
Pluggable in VSPC BASE
Ratings IECEx/ATEX/cUL
ATEX - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
ATEX certificate
ATEX Certificate
Certificate No. (ATEX)
KEMA10ATEX0148X
IEC Ex certificate
IECEX Zertifikat
IECEx - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
cUL certificate
cUL Certificate
Guarantee
Time interval
5 years
Important note
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Tender specification sheets
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2/4 CH FG for four floating-ground driven, intrinsically safe signal cables EX ia. Two-stage protection consisting of coarse and fine protection between all signal cables as well as coarse common mode voltage protection to signal ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification
Surge protection plug for base element VSPC BASE 2/4 CH FG, transverse voltage coarse and fine protection for four floating-ground powered, intrinsically safe signal cables EX ia, coarse common mode voltage protection to earth. Version: 5 V DC
Order No.:
8924550000
Type of connection:
Pluggable in VSPC BASE
Type:
VSPC 3/4WIRE 24VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.:
8924540000
Type of connection:
Pluggable in VSPC BASE
Type:
VSPC 3/4WIRE 5VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Version
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.
8953650000
Type
VSPC 3/4WIRE 5VDC EX
GTIN (EAN)
4032248745807
Qty.
1 pc(s).
Depth
69 mm
Depth (inches)
2.717 inch
Height
90 mm
Height (inches)
3.543 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
53 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
SIL in compliance with IEC 61508
3
MTTF
2,655 a
SFF
95.33 %
λges
43
PFH in 1*10-9 per hour
7
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
ATEX - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
Certificate No. (ATEX)
KEMA10ATEX0148X
IECEx - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
Input power, max. PI
3 W
Input voltage, max. Ui
6 V
Internal capacity, max. CI
<4 nF
Internal inductance, max. LI
0 µH
Temperature class T4/135°C (-40°C ... +85°C) li
350 mA
Temperature class T5/100°C (-40 ° C ... +75°C) li
250 mA
Temperature class T6/85 °C (-40 °C ... +60°C) li
250 mA
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
6 V
Internal capacity, max. CI
4 nF
Internal inductance, max. LI
0 µH
Colour
Light Blue
Design
Terminal, miscellaneous
Optical function display
No
Protection degree
IP20
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
without warning function / function indicator
Pollution severity
2
Surge voltage category
III
Capacitance
2.3 pF
Dielectric strength at FG against PE
≥ 500 V
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Input voltage, max. Ui
6 V
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
6.4 V
Number of poles
2
Overload - failure mode
Modus 2
Protection level UP (typ.)
<800 V
Protection level on output side Wire-PE 1kV/µs, typically
250 V
Protection level on output side Wire-wire 1 kV/µs, typically
35 V
Protection level on output side Wire-wire 8/20 µs, typically
35 V
Protection level, UP GND - PE
450 V
Protection level, UP wire - PE
10 V
Protection level, UP wire - wire
20 V
Pulse-reset capacity
≤ 20 ms
Rated current IN
300 mA
Rated voltage (DC)
3 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
750 KHz
Signalling contact
No
Standards
IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
0.20 Ω
Type of connection
Pluggable in VSPC BASE
ATEX - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
ATEX - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
ATEX certificate
ATEX Certificate
Certificate No. (ATEX)
KEMA10ATEX0148X
IEC Ex certificate
IECEX Zertifikat
IECEx - dust labelling
II 1 D Ex ia IIIC T135 °C …T85 °C Da
IECEx - gas labelling
II 1 G Ex ia IIC T4… T6 Ga
cUL certificate
cUL Certificate
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2/4 CH FG for four floating-ground driven, intrinsically safe signal cables EX ia. Two-stage protection consisting of coarse and fine protection between all signal cables as well as coarse common mode voltage protection to signal ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification
Surge protection plug for base element VSPC BASE 2/4 CH FG, transverse voltage coarse and fine protection for four floating-ground powered, intrinsically safe signal cables EX ia, coarse common mode voltage protection to earth. Version: 5 V DC
Order No.:
8924550000
Type of connection:
Pluggable in VSPC BASE
Type:
VSPC 3/4WIRE 24VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.:
8924540000
Type of connection:
Pluggable in VSPC BASE
Type:
VSPC 3/4WIRE 5VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.