Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
Pluggable arresters for VSPC
Base elements for VSPC
Supply and alert unit for VSPC R arresters
Accessories for the VSPC series
2-level protection for analogue and binary signals
Combi-module protects 24V supply voltage and a current loop
Surge protection for Uk0 /S0 interfaces (telecomm.)
Surge protection for data signals
Surge protection with components such as varistors, gas arresters or suppressor diodes
Serial signal protection such as RS 485 / RS 422
Surge protection for fast signals
Surge protection for fast signals with alert contact
Surge protection for fast signals without alert contact
General ordering data
Version
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.
8924430000
Type
VSPC 2CL HF 5VDC
GTIN (EAN)
4032248696062
Qty.
1 pc(s).
Dimensions and weights
Depth
69 mm
Depth (inches)
2.717 inch
Height
90 mm
Height (inches)
3.543 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
46 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
Probability of failure
SIL in compliance with IEC 61508
3
MTTF
2,537 a
SFF
93.98 %
λges
45
PFH in 1*10-9 per hour
2.95
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
CSA protection data
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
6.4 V
Internal capacity, max. CI
10 nF
Internal inductance, max. LI
0 µH
General data
Number of poles
1
Protection degree
IP20
Colour
orange
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
2 x 10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Fuse
0.5 A
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
6.4 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
<800 V
Protection level on output side Wire-PE 1kV/µs, typically
450 V
Protection level on output side Wire-wire 1 kV/µs, typically
12 V
Protection level on output side Wire-wire 8/20 µs, typically
12 V
Protection level, UP GND - PE
800 V
Protection level, UP wire - PE
450 V
Protection level, UP wire - wire
12 V
Pulse-reset capacity
≤ 20 ms
Rated current IN
450 mA
Rated voltage (DC)
5 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
103 MHz
Signalling contact
No
Standards
IEC 61643-21, HART-compatible
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
2.20 Ω
Connection data
Type of connection
Pluggable in VSPC BASE
Electrical data
Voltage type
DC
Guarantee
Time interval
5 years
Important note
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Tender specification sheets
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 5 V DC.
Type of connection:
Pluggable in VSPC BASE
Order No.:
8924460000
Type:
VSPC 2CL HF 12VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8924510000
Type:
VSPC 2CL HF 24VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Version
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Order No.
8924430000
Type
VSPC 2CL HF 5VDC
GTIN (EAN)
4032248696062
Qty.
1 pc(s).
Depth
69 mm
Depth (inches)
2.717 inch
Height
90 mm
Height (inches)
3.543 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
46 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
SIL in compliance with IEC 61508
3
MTTF
2,537 a
SFF
93.98 %
λges
45
PFH in 1*10-9 per hour
2.95
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
6.4 V
Internal capacity, max. CI
10 nF
Internal inductance, max. LI
0 µH
Number of poles
1
Protection degree
IP20
Colour
orange
Pollution severity
2
Surge voltage category
III
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
2 x 10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Fuse
0.5 A
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
6.4 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
<800 V
Protection level on output side Wire-PE 1kV/µs, typically
450 V
Protection level on output side Wire-wire 1 kV/µs, typically
12 V
Protection level on output side Wire-wire 8/20 µs, typically
12 V
Protection level, UP GND - PE
800 V
Protection level, UP wire - PE
450 V
Protection level, UP wire - wire
12 V
Pulse-reset capacity
≤ 20 ms
Rated current IN
450 mA
Rated voltage (DC)
5 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
103 MHz
Signalling contact
No
Standards
IEC 61643-21, HART-compatible
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
2.20 Ω
Type of connection
Pluggable in VSPC BASE
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 5 V DC.
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UL)
E311081
Type of connection:
Pluggable in VSPC BASE
Order No.:
8924460000
Type:
VSPC 2CL HF 12VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8924510000
Type:
VSPC 2CL HF 24VDC
Version:
Surge protection for instrumentation and control, without warning function / function indicator, UP (L/N-PE) <800 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.