WAZ5 PRO BRIDGE   Product is no longer availableData sheet for information only
         

Icon
Icon
Icon
Icon
 

General ordering data

Version Measuring bridge isolating transformer, Tension-clamp connection
Order No. 8581210000
Type WAZ5 PRO BRIDGE
GTIN (EAN) 4032248234615
Qty. 1 pc(s).
Delivery status Discontinued
Available until 2019-05-31
Alternative product 2456820000

Dimensions and weights

Depth 112.4 mm
Depth (inches) 4.425 inch
Width 17.5 mm
Width (inches) 0.689 inch
Length 92.4 mm
Length (inches) 3.638 inch
Net weight 134 g

Temperatures

Storage temperature -20 °C...85 °C
Operating temperature 0 °C...55

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 94561991-a963-4084-a5f3-dfa3a5c2a27e
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI

Input

Bridge supply voltage +10 V, +5 V, 4.8...10.2 V; offset adjustable; max. 40 mA
Input measurement range 0…10 mV, 0…20 mV, 0…50 mV, 0…100 mV, 0…200 mV, 0…500 mV, -10…+10 mV, -20…+20 mV, -50…+50 mV, -100…+100 mV, -200…+200 mV, -500…+500 mV
Input resistance, voltage > 1 MΩ
Number of inputs 1
Sensor Resistance measuring bridge

Output

Load impedance current ≤ 600 Ω
Number of outputs 1
Offset current max. 100 µA
Offset voltage max. 0.05 V
Output current 0...20 mA, 20...0 mA, 4...20 mA, 20...4 mA
Output voltage, note 0...5 V, 5...0 V, 10...0 V, 0...10 V
Wire break detection Output: 0 V or 0/4 mA
load impedance voltage ≥ 1 kΩ

General data

Accuracy 0.3 % of output range
Configuration DIP switch, Potentiometer
Galvanic isolation 3-way isolator
Power consumption max. 1.9 W at IOUT = 20 mA
Protection degree IP20
Rail TS 35
Step response time typ. < 200 ms
Temperature coefficient ± 250 ppm/K of output range
Voltage supply 24 V DC ± 20 %

Insulation coordination

EMC standards EN 61000-6 /-2
Galvanic isolation 3-way isolator
Impulse withstand voltage 4 kV
Insulation voltage 2 kVeff / 5 s
Insulation voltage input or output/rail 4 kVeff / 1 min.
Insulation voltage input or output/supply 2 kVeff / 5 s
Pollution severity 2
Rated voltage 300 V
Surge voltage category III

Connection data

Type of connection Tension-clamp connection
Stripping length, rated connection 7 mm
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²

Downloads

Approval/Certificate/Document of Conformity
User Documentation
Catalogues Catalogues in PDF-format

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-90
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20
ECLASS 14.0 27-21-01-20

Tender specification sheets

Long specification

Bridge measuring transformer with electrical 3-way isolation, configurable
measurement isolating transformer in 17.5 mm width with external power supply, for
recording, transforming and isolating of measurements from industrial strain gauges.
Standard DC current/voltage signals are available on the output side.
Input voltage range - 500...+ 500 mV can be configured with DIP switches.
Bridge excitation can be switched between 5 V and 10 V, or adjustable from 4.8 to 10.2 V.
I/O signals can be configured via DIP switches.
I/O circuit is electrically isolated from the 24-VDC supply
Add-on housing for TS35 rail mounting
Dimensions: L/W/H 92.4/ 17.5/ 112.4 mm
Tension-clamp connection / Nominal cross-section 1.5 mm²Protection degree: IP 20 Input Resistance measuring bridge / 1 mV / V... 5 mV / V
Bridge sensitivity - 500 mV...+500 mV switchable in 12 rangesInput resistance > 1 MOhm
Bridge supply 5 V /10 V / 4.8....10, V
Output 0...5 V / 0...10 V/ 0(4)...20 mA also inverseLoad resistance 1 kOhm/ voltage
Temperature coefficient typ. 250 ppm / KTransmission errortyp. 0.3 % of input< 600 Ohm/ Strom //>Step response time
Auxiliary power24 VDC +/- 25 %Ambient temperature range 0...55 °C




Isolation EN 50178, 3-way isolation up to 4 kV of all circuits against each other
Test voltage2 kV input against output against auxiliary power
Rated
voltage 300 V AC/DC at overvoltage category III and pollution degree 2
Approvals cULus




Type WAZ5 PRO Bridge

Short specification

Bridge measuring transformer with electrical 3-way isolation, configurable
measurement isolating transformer in 17.5 mm width with external power supply, for
recording, transforming and isolating of measurements from industrial strain gauges.
Standard DC current/voltage signals are available on the output side.
Input voltage range - 500...+ 500 mV can be configured with DIP switches.
Bridge excitation can be switched between 5 V and 10 V, or adjustable from 4.8 to 10.2 V.

I/O signals can be configured via DIP switches.
I/O circuit is electrically isolated from the 24-VDC supply


Approvals

Approvals CE CULUS
ROHS Conform
UL File Number Search UL Website
Certificate no. (cULus) E141197

Related products

Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts