Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Universal signal converter
Current measuring transducer
Frequency signal converter
Limit- & current monitoring
Serial interface converter
Temperature transducer
Signal converter
Rectifier modules
WAS5 CCC LP 0-20/0-20MA
Do not use product for new developmentsOnly remaining stock available
General ordering data
Version
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA
Order No.
8463580000
Type
WAS5 CCC LP 0-20/0-20MA
GTIN (EAN)
4032248049455
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-12-31
Alternative product
7760054124
Dimensions and weights
Depth
112.4 mm
Depth (inches)
4.425 inch
Width
17.5 mm
Width (inches)
0.689 inch
Length
92.4 mm
Length (inches)
3.638 inch
Net weight
152 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
0 °C...70 °C
Humidity at operating temperature
0...95 % (no condensation)
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
1,049 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
b25f3b7c-b874-4a4e-a8b2-4f423a7e2a65
RoHS Compliance Status
Compliant
Input
Input current
0(4)...20 mA current loop
Number of inputs
2
Pick-up current
<100 µA
Voltage drop
Approx. 3 V at RL = 0 Ω; approx. 13 V at RL = 500 Ω; (IIN =20 mA)
Output
Load impedance current
≤ 500 Ω
Number of outputs
2
Output current
0...20 mA, 4...20 mA
Output (digital)
Max. switching voltage, AC
0 V
Rated switching current
0.1 A
General data
Accuracy
<0.1 % of end value
Configuration
none
Galvanic isolation
Passive isolator
Protection degree
IP20
Rail
TS 35
Temperature coefficient
≤ 50 ppm/K of final value
Voltage supply
via the input measuring circuit
Insulation coordination
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
Passive isolator
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 1 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Connection data
Type of connection
Screw connection
Stripping length, rated connection
7 mm
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.5 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Important note
Product information
This product will soon be replaced by a new product. Please do not use with new systems. Please contact our technical support.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Tender specification sheets
Long specification
Standard signal passive isolator two-channel, input-loop powered 2-channel signal passive isolator in 17.5 mm width with input current loop feed,for transmitting and isolating analogue DC current signals from 0/4 to 20 mA Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 92.4/17.5/ 112.4 mm Screw connection /nominal cross-section2.5 mm²Protection degree: IP20 Input2 x 0/4 to 20 mA Output 2 x 0/4 to 20 mA Voltage drop approx. 3 V at RL 0 Ohm, 13 V at RL = 500 Ohm (20 mA)Load resistance Transmission error Auxiliary power 0/4...20 mA Input current loopAmbient temperature range -25 °C...+70 °C
Isolation EN 50178 , 2-way isolation up to 4 kV AC/DC Test voltage6 kV Rated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus, cULusEX, CSA, GL
Type WAS5 CCC-LP 0-20/0-20mA
Short specification
Standard signal passive isolator two-channel, input-loop powered 2-channel signal passive isolator in 17.5 mm width with input current loop feed, for transmitting and isolating analogue DC current signals from 0/4 to 20 mA
Type of connection:
Tension-clamp connection
Order No.:
8447140000
Type:
WAZ4 VVC DC 0-10/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8445050000
Type:
WAZ4 CVC DC 4-20/0-10V
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8540300000
Type:
WAZ5 VCC 0-10V/4-20MA
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8540340000
Type:
WAZ5 VVC 0-10V/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Version
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA
Order No.
8463580000
Type
WAS5 CCC LP 0-20/0-20MA
GTIN (EAN)
4032248049455
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-12-31
Alternative product
7760054124
Depth
112.4 mm
Depth (inches)
4.425 inch
Width
17.5 mm
Width (inches)
0.689 inch
Length
92.4 mm
Length (inches)
3.638 inch
Net weight
152 g
Storage temperature
-40 °C...80 °C
Operating temperature
0 °C...70 °C
Humidity at operating temperature
0...95 % (no condensation)
SIL in compliance with IEC 61508
None
MTTF
1,049 a
REACH SVHC
Lead 7439-92-1
SCIP
b25f3b7c-b874-4a4e-a8b2-4f423a7e2a65
RoHS Compliance Status
Compliant
Input current
0(4)...20 mA current loop
Number of inputs
2
Pick-up current
<100 µA
Voltage drop
Approx. 3 V at RL = 0 Ω; approx. 13 V at RL = 500 Ω; (IIN =20 mA)
Load impedance current
≤ 500 Ω
Number of outputs
2
Output current
0...20 mA, 4...20 mA
Max. switching voltage, AC
0 V
Rated switching current
0.1 A
Accuracy
<0.1 % of end value
Configuration
none
Galvanic isolation
Passive isolator
Protection degree
IP20
Rail
TS 35
Temperature coefficient
≤ 50 ppm/K of final value
Voltage supply
via the input measuring circuit
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
Passive isolator
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 1 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Type of connection
Screw connection
Stripping length, rated connection
7 mm
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.5 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Product information
This product will soon be replaced by a new product. Please do not use with new systems. Please contact our technical support.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Long specification
Standard signal passive isolator two-channel, input-loop powered 2-channel signal passive isolator in 17.5 mm width with input current loop feed,for transmitting and isolating analogue DC current signals from 0/4 to 20 mA Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 92.4/17.5/ 112.4 mm Screw connection /nominal cross-section2.5 mm²Protection degree: IP20 Input2 x 0/4 to 20 mA Output 2 x 0/4 to 20 mA Voltage drop approx. 3 V at RL 0 Ohm, 13 V at RL = 500 Ohm (20 mA)Load resistance Transmission error Auxiliary power 0/4...20 mA Input current loopAmbient temperature range -25 °C...+70 °C
Isolation EN 50178 , 2-way isolation up to 4 kV AC/DC Test voltage6 kV Rated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus, cULusEX, CSA, GL
Type WAS5 CCC-LP 0-20/0-20mA
Short specification
Standard signal passive isolator two-channel, input-loop powered 2-channel signal passive isolator in 17.5 mm width with input current loop feed, for transmitting and isolating analogue DC current signals from 0/4 to 20 mA
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Certificate no. (cULusEX)
E223527
Type of connection:
Tension-clamp connection
Order No.:
8447140000
Type:
WAZ4 VVC DC 0-10/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8445050000
Type:
WAZ4 CVC DC 4-20/0-10V
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8540300000
Type:
WAZ5 VCC 0-10V/4-20MA
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Type of connection:
Tension-clamp connection
Order No.:
8540340000
Type:
WAZ5 VVC 0-10V/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.