Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
MCZ OVP 24 V AC/DC
MCZ OVP 48 V UC
MCZ OVP HF
General ordering data
Version
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.
8449150000
Type
MCZ OVP TAZ DIODE 24VDC
GTIN (EAN)
4008190128227
Qty.
10 pc(s).
Dimensions and weights
Depth
63.5 mm
Depth (inches)
2.5 inch
Height
91 mm
Height (inches)
3.583 inch
Width
6 mm
Width (inches)
0.236 inch
Net weight
24.8 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
REACH SVHC
Lead 7439-92-1
SCIP
c9db83e7-2b25-44e1-8d26-da64d426373f
General data
Protection degree
IP20
Colour
black
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Capacitance
1 nF
Discharge current, max. (8/20 µs)
112 A
Fuse
10A
Max. continuous voltage, Uc (AC)
30 V
Operating current, Imax.
13 A
Operating voltage
26 A
Protection level on output side Wire-PE 1kV/µs, typically
55 V
Protection level on output side Wire-PE 8/20 µs, typically
65 V
Protection level on output side Wire-wire 1 kV/µs, typically
55 V
Protection level on output side Wire-wire 8/20 µs, typically
65 V
Rated current IN
13 A
Rated voltage (DC)
24 V
Rated voltage (DC), max.
30 V
Response time
≤ 100 ps
Voltage type
DC
Volume resistance
0.20 Ω
Connection data
Cross-section
1.5 mm²
Stripping length
8 mm
Wire connection method
Spring connection
Type of connection
Tension-clamp connection
Stripping length, rated connection
8 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Blade size
0.6 x 3.5 mm
Electrical data
Voltage type
DC
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
8472880000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VAC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448920000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448960000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8704240000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448940000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448970000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8823280000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8449160000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP TAZ DIODE 24VUC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8449140000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP VARISTOR S10K30
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Version
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.
8449150000
Type
MCZ OVP TAZ DIODE 24VDC
GTIN (EAN)
4008190128227
Qty.
10 pc(s).
Depth
63.5 mm
Depth (inches)
2.5 inch
Height
91 mm
Height (inches)
3.583 inch
Width
6 mm
Width (inches)
0.236 inch
Net weight
24.8 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a
REACH SVHC
Lead 7439-92-1
SCIP
c9db83e7-2b25-44e1-8d26-da64d426373f
Protection degree
IP20
Colour
black
Pollution severity
2
Surge voltage category
III
Capacitance
1 nF
Discharge current, max. (8/20 µs)
112 A
Fuse
10A
Max. continuous voltage, Uc (AC)
30 V
Operating current, Imax.
13 A
Operating voltage
26 A
Protection level on output side Wire-PE 1kV/µs, typically
55 V
Protection level on output side Wire-PE 8/20 µs, typically
65 V
Protection level on output side Wire-wire 1 kV/µs, typically
55 V
Protection level on output side Wire-wire 8/20 µs, typically
65 V
Rated current IN
13 A
Rated voltage (DC)
24 V
Rated voltage (DC), max.
30 V
Response time
≤ 100 ps
Voltage type
DC
Volume resistance
0.20 Ω
Cross-section
1.5 mm²
Stripping length
8 mm
Wire connection method
Spring connection
Type of connection
Tension-clamp connection
Stripping length, rated connection
8 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Blade size
0.6 x 3.5 mm
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
8472880000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VAC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448920000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448960000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8704240000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP CL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448940000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8448970000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8823280000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP SL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8449160000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP TAZ DIODE 24VUC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.:
8449140000
Type of connection:
Tension-clamp connection
Type:
MCZ OVP VARISTOR S10K30
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.