Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
MCZ OVP 24 V AC/DC
MCZ OVP 48 V UC
MCZ OVP HF
General ordering data
Version
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.
8449140000
Type
MCZ OVP VARISTOR S10K30
GTIN (EAN)
4008190124830
Qty.
10 pc(s).
Alternative product
1064540000
Dimensions and weights
Depth
63.5 mm
Depth (inches)
2.5 inch
Height
91 mm
Height (inches)
3.583 inch
Width
6 mm
Width (inches)
0.236 inch
Net weight
26 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
-40 °C...60
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
c9db83e7-2b25-44e1-8d26-da64d426373f
RoHS Compliance Status
Compliant
General data
Colour
black
Design
Terminal
Height with TS 35
63.5 mm
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Capacitance
2,700 pF
Discharge current, max. (8/20 µs)
125 A
Fuse
10A
Lightning test current Iimp (10/350 µs)
< 0.5 kA
Max. continuous voltage, Uc (AC)
30 V
Operating current, Imax.
13 A
Operating voltage
38 V
Protection level on output side Wire-PE 1kV/µs, typically
45 V
Protection level on output side Wire-PE 8/20 µs, typically
55 V
Protection level on output side Wire-wire 1 kV/µs, typically
45 V
Protection level on output side Wire-wire 8/20 µs, typically
55 V
Rated current IN
13 A
Rated voltage (AC)
24 V
Rated voltage (DC)
24 V
Rated voltage (DC), max.
38 V
Response time
≤ 25 ns
Voltage type
AC/DC
Volume resistance
0.20 Ω
Connection data
Cross-section
1.5 mm²
Stripping length
8 mm
Wire connection method
Spring connection
Type of connection
Tension-clamp connection
Stripping length, rated connection
8 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Blade size
0.6 x 3.5 mm
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8472880000
Type:
MCZ OVP CL 24VAC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448920000
Type:
MCZ OVP CL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448960000
Type:
MCZ OVP CL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8704240000
Type:
MCZ OVP CL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448940000
Type:
MCZ OVP SL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448970000
Type:
MCZ OVP SL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8823280000
Type:
MCZ OVP SL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8449150000
Type:
MCZ OVP TAZ DIODE 24VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8449160000
Type:
MCZ OVP TAZ DIODE 24VUC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Version
Surge protection for instrumentation and control, Surge protection for measurement and control
Order No.
8449140000
Type
MCZ OVP VARISTOR S10K30
GTIN (EAN)
4008190124830
Qty.
10 pc(s).
Alternative product
1064540000
Depth
63.5 mm
Depth (inches)
2.5 inch
Height
91 mm
Height (inches)
3.583 inch
Width
6 mm
Width (inches)
0.236 inch
Net weight
26 g
Storage temperature
-20 °C...85 °C
Operating temperature
-40 °C...60
REACH SVHC
Lead 7439-92-1
SCIP
c9db83e7-2b25-44e1-8d26-da64d426373f
RoHS Compliance Status
Compliant
Colour
black
Design
Terminal
Height with TS 35
63.5 mm
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control
Pollution severity
2
Surge voltage category
III
Capacitance
2,700 pF
Discharge current, max. (8/20 µs)
125 A
Fuse
10A
Lightning test current Iimp (10/350 µs)
< 0.5 kA
Max. continuous voltage, Uc (AC)
30 V
Operating current, Imax.
13 A
Operating voltage
38 V
Protection level on output side Wire-PE 1kV/µs, typically
45 V
Protection level on output side Wire-PE 8/20 µs, typically
55 V
Protection level on output side Wire-wire 1 kV/µs, typically
45 V
Protection level on output side Wire-wire 8/20 µs, typically
55 V
Rated current IN
13 A
Rated voltage (AC)
24 V
Rated voltage (DC)
24 V
Rated voltage (DC), max.
38 V
Response time
≤ 25 ns
Voltage type
AC/DC
Volume resistance
0.20 Ω
Cross-section
1.5 mm²
Stripping length
8 mm
Wire connection method
Spring connection
Type of connection
Tension-clamp connection
Stripping length, rated connection
8 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Blade size
0.6 x 3.5 mm
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8472880000
Type:
MCZ OVP CL 24VAC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448920000
Type:
MCZ OVP CL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448960000
Type:
MCZ OVP CL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8704240000
Type:
MCZ OVP CL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448940000
Type:
MCZ OVP SL 24VDC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8448970000
Type:
MCZ OVP SL 24VUC 1,25A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8823280000
Type:
MCZ OVP SL FG 24VUC 0,5A
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8449150000
Type:
MCZ OVP TAZ DIODE 24VDC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
Type of connection:
Tension-clamp connection
Order No.:
8449160000
Type:
MCZ OVP TAZ DIODE 24VUC
Version:
Surge protection for instrumentation and control, Surge protection for measurement and control
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.