Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Controls
I/O Systems
Industrial Ethernet
Touch Panels
Engineering and Visualisation Tools
Measuring and Monitoring Systems
Automated Machine Learning
easyConnect
Energy Meter
Energy Analyser
Energy / Data Logger
Current transformer
Retrofit energy solutions
Mechanical- & electronic sensors
Accessories
Rogowski coils
Split core current transformer
Mini current transformer
Plug-on current transformer
Difference current transformer (Residual current monitoring, RCM)
Current transformer with analogue output
General ordering data
Version
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 80.00 mm, Split-core current transformer
Order No.
2656290000
Type
KCMA-RCM-812D
GTIN (EAN)
4050118666342
Qty.
1 pc(s).
Dimensions and weights
Depth
198 mm
Depth (inches)
7.795 inch
Width
58 mm
Width (inches)
2.283 inch
Length
155 mm
Length (inches)
6.102 inch
Net weight
240 g
Temperatures
Operating temperature
-5 °C...45 °C
Environmental Product Compliance
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Measuring current input
Residual current measuring
Yes
Dimensions of live conductors
Type of conductor
Insulated conductor only
Round conductor
80 mm
Rail
80 x 120 mm
Installation location
Indoor use
Electrical attributes
Frequency band
30…1000 Hz
Primary conductor temperature
70 °C
Primary current
18 A
Secondary current
0...0.04 A
Tolerance class
1
Transmission ratio
1:600
General data
Manufacturer
MBS AG
Technical properties
Insulation class
E
Nominal frequency
50 Hz
Protection degree
IP20
Thermal rated continuous current Ithermal
60 x Irated for 1 second
Insulation coordination
Standard
EN 60044⁄1
Tolerance class
1
Classifications
ETIM 6.0
EC002048
ETIM 7.0
EC002048
ETIM 8.0
EC002048
ETIM 9.0
EC002048
ECLASS 9.0
27-21-09-02
ECLASS 9.1
27-21-09-02
ECLASS 10.0
27-21-09-02
ECLASS 11.0
27-21-09-02
ECLASS 12.0
27-21-09-02
ECLASS 13.0
27-21-09-02
ECLASS 14.0
27-21-09-02
Order No.:
2603420000
Type:
CMA-RCM-DACT-20
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 20.00 mm, closed current transformer
Order No.:
2603430000
Type:
CMA-RCM-DACT-35
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 35.00 mm, closed current transformer
Order No.:
2603440000
Type:
CMA-RCM-DACT-60
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 60.00 mm, closed current transformer
Order No.:
2603450000
Type:
CMA-RCM-DACT-120
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 120.00 mm, closed current transformer
Order No.:
2656270000
Type:
KCMA-RCM-23D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 20.00 mm, Split-core current transformer
Order No.:
2656280000
Type:
KCMA-RCM-58D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 50.00 mm, Split-core current transformer
Version
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 80.00 mm, Split-core current transformer
Order No.
2656290000
Type
KCMA-RCM-812D
GTIN (EAN)
4050118666342
Qty.
1 pc(s).
Depth
198 mm
Depth (inches)
7.795 inch
Width
58 mm
Width (inches)
2.283 inch
Length
155 mm
Length (inches)
6.102 inch
Net weight
240 g
Operating temperature
-5 °C...45 °C
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Residual current measuring
Yes
Type of conductor
Insulated conductor only
Round conductor
80 mm
Rail
80 x 120 mm
Installation location
Indoor use
Frequency band
30…1000 Hz
Primary conductor temperature
70 °C
Primary current
18 A
Secondary current
0...0.04 A
Tolerance class
1
Transmission ratio
1:600
Insulation class
E
Nominal frequency
50 Hz
Protection degree
IP20
Thermal rated continuous current Ithermal
60 x Irated for 1 second
Standard
EN 60044⁄1
Tolerance class
1
ETIM 6.0
EC002048
ETIM 7.0
EC002048
ETIM 8.0
EC002048
ETIM 9.0
EC002048
ECLASS 9.0
27-21-09-02
ECLASS 9.1
27-21-09-02
ECLASS 10.0
27-21-09-02
ECLASS 11.0
27-21-09-02
ECLASS 12.0
27-21-09-02
ECLASS 13.0
27-21-09-02
ECLASS 14.0
27-21-09-02
Order No.:
2603420000
Type:
CMA-RCM-DACT-20
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 20.00 mm, closed current transformer
Order No.:
2603430000
Type:
CMA-RCM-DACT-35
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 35.00 mm, closed current transformer
Order No.:
2603440000
Type:
CMA-RCM-DACT-60
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 60.00 mm, closed current transformer
Order No.:
2603450000
Type:
CMA-RCM-DACT-120
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 120.00 mm, closed current transformer
Order No.:
2656270000
Type:
KCMA-RCM-23D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 20.00 mm, Split-core current transformer
Order No.:
2656280000
Type:
KCMA-RCM-58D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 50.00 mm, Split-core current transformer
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.