Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Controls
I/O Systems
Industrial Ethernet
Touch Panels
Engineering and Visualisation Tools
Measuring and Monitoring Systems
Automated Machine Learning
easyConnect
Energy Meter
Energy Analyser
Energy / Data Logger
Current transformer
Retrofit energy solutions
Mechanical- & electronic sensors
Accessories
Rogowski coils
Split core current transformer
Mini current transformer
Plug-on current transformer
Difference current transformer (Residual current monitoring, RCM)
Current transformer with analogue output
General ordering data
Version
Residual current transformer, Primary current: 25 A, Round conductor: 60.00 mm, closed current transformer
Order No.
2603440000
Type
CMA-RCM-DACT-60
GTIN (EAN)
4050118663594
Qty.
1 pc(s).
Dimensions and weights
Depth
37 mm
Depth (inches)
1.457 inch
Height
117 mm
Height (inches)
4.606 inch
Width
135 mm
Width (inches)
5.315 inch
Net weight
240 g
Temperatures
Storage temperature
-25 °C...70 °C
Operating temperature
-10 °C...70 °C
Environmental Product Compliance
RoHS Compliance Status
Compliant
REACH SVHC
/
Measuring current input
Residual current measuring
Yes
Dimensions of live conductors
Type of conductor
Insulated conductor only
Round conductor
60 mm
Installation location
Indoor use
Electrical attributes
Frequency band
30 Hz…3 kHz
Load
0 VA
Primary current
25 A
Secondary current
0...0.04 A
Tolerance class
1
Transmission ratio
1:600
General data
Manufacturer
MBS AG
Technical properties
Coil resistance
8 Ω
Measurement accuracy
Class 1 (IEC 6206-21)
Protection degree
IP40
Input
Input measurement range
0.02…2 A / 0.25…25 A depending on terminal assignment
Insulation coordination
Galvanic isolation
yes
Impulse withstand voltage
8 kV
Pollution severity
3
Rated voltage
800 V
Standard
EN 60044⁄1
Tolerance class
1
Classifications
ETIM 6.0
EC002048
ETIM 7.0
EC002048
ETIM 8.0
EC002048
ETIM 9.0
EC002048
ECLASS 9.0
27-21-09-02
ECLASS 9.1
27-21-09-02
ECLASS 10.0
27-21-09-02
ECLASS 11.0
27-21-09-02
ECLASS 12.0
27-21-09-02
ECLASS 13.0
27-21-09-02
ECLASS 14.0
27-21-09-02
Order No.:
2603420000
Type:
CMA-RCM-DACT-20
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 20.00 mm, closed current transformer
Order No.:
2603430000
Type:
CMA-RCM-DACT-35
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 35.00 mm, closed current transformer
Order No.:
2603450000
Type:
CMA-RCM-DACT-120
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 120.00 mm, closed current transformer
Order No.:
2656270000
Type:
KCMA-RCM-23D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 20.00 mm, Split-core current transformer
Order No.:
2656280000
Type:
KCMA-RCM-58D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 50.00 mm, Split-core current transformer
Order No.:
2656290000
Type:
KCMA-RCM-812D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 80.00 mm, Split-core current transformer
Version
Residual current transformer, Primary current: 25 A, Round conductor: 60.00 mm, closed current transformer
Order No.
2603440000
Type
CMA-RCM-DACT-60
GTIN (EAN)
4050118663594
Qty.
1 pc(s).
Depth
37 mm
Depth (inches)
1.457 inch
Height
117 mm
Height (inches)
4.606 inch
Width
135 mm
Width (inches)
5.315 inch
Net weight
240 g
Storage temperature
-25 °C...70 °C
Operating temperature
-10 °C...70 °C
RoHS Compliance Status
Compliant
REACH SVHC
/
Residual current measuring
Yes
Type of conductor
Insulated conductor only
Round conductor
60 mm
Installation location
Indoor use
Frequency band
30 Hz…3 kHz
Load
0 VA
Primary current
25 A
Secondary current
0...0.04 A
Tolerance class
1
Transmission ratio
1:600
Coil resistance
8 Ω
Measurement accuracy
Class 1 (IEC 6206-21)
Protection degree
IP40
Input measurement range
0.02…2 A / 0.25…25 A depending on terminal assignment
Galvanic isolation
yes
Impulse withstand voltage
8 kV
Pollution severity
3
Rated voltage
800 V
Standard
EN 60044⁄1
Tolerance class
1
ETIM 6.0
EC002048
ETIM 7.0
EC002048
ETIM 8.0
EC002048
ETIM 9.0
EC002048
ECLASS 9.0
27-21-09-02
ECLASS 9.1
27-21-09-02
ECLASS 10.0
27-21-09-02
ECLASS 11.0
27-21-09-02
ECLASS 12.0
27-21-09-02
ECLASS 13.0
27-21-09-02
ECLASS 14.0
27-21-09-02
Order No.:
2603420000
Type:
CMA-RCM-DACT-20
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 20.00 mm, closed current transformer
Order No.:
2603430000
Type:
CMA-RCM-DACT-35
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 35.00 mm, closed current transformer
Order No.:
2603450000
Type:
CMA-RCM-DACT-120
Version:
Residual current transformer, Primary current: 25 A, Round conductor: 120.00 mm, closed current transformer
Order No.:
2656270000
Type:
KCMA-RCM-23D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 20.00 mm, Split-core current transformer
Order No.:
2656280000
Type:
KCMA-RCM-58D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 50.00 mm, Split-core current transformer
Order No.:
2656290000
Type:
KCMA-RCM-812D
Version:
Residual current transformer (RCM), Primary current: 18 A, Round conductor: 80.00 mm, Split-core current transformer
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.