Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Switched-mode power supply units
Electronic load monitoring
Communication modules
Uninterruptible power supply
DC/DC converter
Diode- and redundancy modules
Pre charge unit
Decentralised switched-mode power supply units IP65
Decentralised electronic load monitoring IP65
Accessories
Connect Power PROtop
Connect Power PROmax
Connect Power PROeco
Connect Power PRObas
Connect Power INSTA POWER
Connect Power PRO PM
Connect Power PRO-M
Connect Power single-phase PRO-M
General ordering data
Version
Power supply, switch-mode power supply unit
Order No.
1412540000
Type
CP M SNT 500W 36V 13.5A
GTIN (EAN)
4050118214093
Qty.
1 pc(s).
Delivery status
Discontinued
Dimensions and weights
Depth
150 mm
Depth (inches)
5.905 inch
Height
130 mm
Height (inches)
5.118 inch
Width
121 mm
Width (inches)
4.764 inch
Net weight
2,200 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
RoHS Compliance Status
Compliant
Input
AC current consumption
2.4 A @ 230 V AC / 4.8 A @ 115 V AC
AC input voltage range
85...264 V AC (derating at 100 V AC)
DC current consumption
1.5 A @ 370 V DC / 4.6 A @ 120 V DC
DC input voltage range
80...370 V DC (Derating @ 120 V DC)
Frequency range AC
47...63 Hz
Input fuse
Yes
Input fuse (internal)
Yes
Inrush current
5 A
Rated input voltage
100...240 V AC (wide-range input)
Recommended back-up fuse
6 A / DI, safety fuse 16 A, Char. B, circuit breaker 6…8 A, Char. C, circuit breaker
Wire connection method
Screw connection
Output
Continuous output current @ UNominal
16.2 A @ 45°C, 13.5 A @ 60°C, 10.2 A@ 70°C
Nominal output current for Unom
13.5 A @ 60°C
Output power
500 W
Output voltage type
DC
Output voltage, max.
38 V
Output voltage, min.
29 V
Output voltage, note
(adjustable via potentiometer on front)
Overload protection
Yes
Parallel connection option
yes, max. 3
Protection against inverse voltage
Yes
Rated output voltage
36 V DC ± 1 %
Residual ripple, breaking spikes
< 50 mVss @ 36 V DC
Wire connection method
Screw connection
General data
AC failure bridging time @ Inom
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
Current limiting
> 120% IN
Degree of efficiency
90 % at 230 V AC / > 85 % at 115 V AC
Housing version
Metal, corrosion resistant
Indication
Operation, green LED
Mounting position, installation notice
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Power factor (approx.)
> 0.98 @ 230 V AC / > 0.99 @ 115 V AC
Protection against over-heating
Yes
Protection against reverse voltages from the load
40…45 V DC
Protection degree
IP20
Short-circuit protection
Yes
Surge voltage category
II
EMC / shock / vibration
Interference immunity test acc. to
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips)
Limiting of mains voltage harmonic currents
According to EN 61000-3-2
Noise emission in accordance with EN55032
Class B
Shock resistance IEC 60068-2-27
30 g in all directions
Vibration resistance IEC 60068-2-6
1 g according to EN 50178
Insulation coordination
Insulation voltage
3 kV input/ouput; 2 kV input/earth; 0.5 kV output/earth
Pollution severity
2
Protection class
I, with PE connection
Surge voltage category
II
electrical isolation, input-earth
2 kV
electrical isolation, input-output
3 kV
electrical isolation, output-earth
0.5 kV
Electrical safety (applied standards)
Electrical machine equipment
Acc. to EN60204
For use with electronic equipment
Acc. to EN50178 / VDE0160
Protection against dangerous shock currents
Acc. to VDE0106-101
Protective separation / protection against electrical shock
VDE0100-410 / acc. to DIN57100-410
Safety transformers for switch-mode power supplies
According to EN 61558-2-16
Connection data (input)
Conductor cross-section, AWG/kcmil , max.
10
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
3 for L/N/PE
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Wire connection cross section, flexible (input), max.
2.5 mm²
Connection data (output)
Conductor cross-section, AWG/kcmil , max.
10
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
5 (++ / ---)
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Classifications
ETIM 6.0
EC002540
ETIM 7.0
EC002540
ETIM 8.0
EC002540
ETIM 9.0
EC002540
ECLASS 9.0
27-04-07-01
ECLASS 9.1
27-04-07-01
ECLASS 10.0
27-04-07-01
ECLASS 11.0
27-04-07-01
ECLASS 12.0
27-04-07-01
ECLASS 13.0
27-04-07-01
ECLASS 14.0
27-04-07-01
Approvals
Approvals
ROHS
Conform
Version
Power supply, switch-mode power supply unit
Order No.
1412540000
Type
CP M SNT 500W 36V 13.5A
GTIN (EAN)
4050118214093
Qty.
1 pc(s).
Delivery status
Discontinued
Depth
150 mm
Depth (inches)
5.905 inch
Height
130 mm
Height (inches)
5.118 inch
Width
121 mm
Width (inches)
4.764 inch
Net weight
2,200 g
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70
REACH SVHC
Lead 7439-92-1
RoHS Compliance Status
Compliant
AC current consumption
2.4 A @ 230 V AC / 4.8 A @ 115 V AC
AC input voltage range
85...264 V AC (derating at 100 V AC)
DC current consumption
1.5 A @ 370 V DC / 4.6 A @ 120 V DC
DC input voltage range
80...370 V DC (Derating @ 120 V DC)
Frequency range AC
47...63 Hz
Input fuse
Yes
Input fuse (internal)
Yes
Inrush current
5 A
Rated input voltage
100...240 V AC (wide-range input)
Recommended back-up fuse
6 A / DI, safety fuse 16 A, Char. B, circuit breaker 6…8 A, Char. C, circuit breaker
Wire connection method
Screw connection
Continuous output current @ UNominal
16.2 A @ 45°C, 13.5 A @ 60°C, 10.2 A@ 70°C
Nominal output current for Unom
13.5 A @ 60°C
Output power
500 W
Output voltage type
DC
Output voltage, max.
38 V
Output voltage, min.
29 V
Output voltage, note
(adjustable via potentiometer on front)
Overload protection
Yes
Parallel connection option
yes, max. 3
Protection against inverse voltage
Yes
Rated output voltage
36 V DC ± 1 %
Residual ripple, breaking spikes
< 50 mVss @ 36 V DC
Wire connection method
Screw connection
AC failure bridging time @ Inom
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
Current limiting
> 120% IN
Degree of efficiency
90 % at 230 V AC / > 85 % at 115 V AC
Housing version
Metal, corrosion resistant
Indication
Operation, green LED
Mounting position, installation notice
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between.
Power factor (approx.)
> 0.98 @ 230 V AC / > 0.99 @ 115 V AC
Protection against over-heating
Yes
Protection against reverse voltages from the load
40…45 V DC
Protection degree
IP20
Short-circuit protection
Yes
Surge voltage category
II
Interference immunity test acc. to
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips)
Limiting of mains voltage harmonic currents
According to EN 61000-3-2
Noise emission in accordance with EN55032
Class B
Shock resistance IEC 60068-2-27
30 g in all directions
Vibration resistance IEC 60068-2-6
1 g according to EN 50178
Insulation voltage
3 kV input/ouput; 2 kV input/earth; 0.5 kV output/earth
Pollution severity
2
Protection class
I, with PE connection
Surge voltage category
II
electrical isolation, input-earth
2 kV
electrical isolation, input-output
3 kV
electrical isolation, output-earth
0.5 kV
Electrical machine equipment
Acc. to EN60204
For use with electronic equipment
Acc. to EN50178 / VDE0160
Protection against dangerous shock currents
Acc. to VDE0106-101
Protective separation / protection against electrical shock
VDE0100-410 / acc. to DIN57100-410
Safety transformers for switch-mode power supplies
According to EN 61558-2-16
Conductor cross-section, AWG/kcmil , max.
10
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
3 for L/N/PE
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Wire connection cross section, flexible (input), max.
2.5 mm²
Conductor cross-section, AWG/kcmil , max.
10
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section, rigid , max.
6 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Number of terminals
5 (++ / ---)
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
ETIM 6.0
EC002540
ETIM 7.0
EC002540
ETIM 8.0
EC002540
ETIM 9.0
EC002540
ECLASS 9.0
27-04-07-01
ECLASS 9.1
27-04-07-01
ECLASS 10.0
27-04-07-01
ECLASS 11.0
27-04-07-01
ECLASS 12.0
27-04-07-01
ECLASS 13.0
27-04-07-01
ECLASS 14.0
27-04-07-01
Approvals
ROHS
Conform
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.