Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible measuring transducer - ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Network-compatible current measuring transducers ACT20C
Voltage converter with serial interface ACT20C
ACT20C-AI-AO-MTCP
Do not use product for new developmentsOnly remaining stock available
General ordering data
Order No.
1334490000
Type
ACT20C-AI-AO-MTCP
GTIN (EAN)
4050118137675
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2023-05-31
Dimensions and weights
Depth
113.6 mm
Depth (inches)
4.472 inch
Width
22.5 mm
Width (inches)
0.886 inch
Length
119.2 mm
Length (inches)
4.693 inch
Net weight
169 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...70 °C
Humidity
0...95 % (no condensation)
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input current
0...20 mA, 4...20 mA
Input voltage
0(2)…10 V
Number of inputs
1
Sensor supply
> 17 V DC at 20 mA
Interface 1
Addressing
DHCP or manual adjustment
Interface
RJ45: female-female, Cat.5 to 100 MHz, Jack plug for CBX200
Protocol
FDT/DTM, Modbus/TCP
Output
Load impedance current
≤ 500 Ω
Number of outputs
1
Output current
0...20 mA, 4...20 mA
Output voltage, note
0...10 V
load impedance voltage
≥ 10 kΩ
Output (analogue)
Load resistance current
≤ 500 Ω
Load resistance voltage
≥ 10 kΩ
Output current
0(4)...20 mA
Output voltage
0...10 V
Transmit function
direct or inverted
General data
Accuracy
< 0.15% end value (+ 0.05% > 55 °C), Current: 1 uA / 30 uA (+ 10 uA > 55°C), Voltage: 1 mV / 15 mV (+ 5 mV > 55°C)
Configuration
FDT/DTM (Ethernet or service interface)
Galvanic isolation
4-way isolator;, between input / output / power supply / Ethernet
Power consumption
≤ 3.5 W
Protection degree
IP20
Rail
TS 35
Temperature coefficient
≤ 0.01 % / °C
Voltage supply
24 V DC ± 25 %
Insulation coordination
EMC standards
EN 61326-1:2006
Galvanic isolation
4-way isolator;, between input / output / power supply / Ethernet
Pollution severity
2
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional earth to supply ⁄ Ethernet interface
31.2 V DC / 0.9 kV rms in secondary electrical circuits, basic insulation
Rated voltage ⁄ test voltage: functional earth to input ⁄ output
300 Vrms / 1.1 kV rms in secondary electrical circuits, basic insulation
Rated voltage ⁄ test voltage: input/output to output/input ⁄ supply⁄ Ethernet interface
300 Vrms / 1.7 kV rms in secondary electrical circuits, reinforced insulation
Recommendations
Namur NE43, Namur NE44, Namur NE107
Connection data
Type of connection
Screw connection/ RJ45 plug-in connector
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Important note
Product information
With the ACT20C, Weidmüller is presenting a completely new type of signal converter. The compact module is equipped with an Ethernet connection and provides, in addition to signals, precise information on the status of sensors, signal processing and cabling.
ACT20C, as a signal converter, isolates, scales and converts analogue current and voltage signals; it can be configured directly with the "WI-Manager" software or via an Ethernet network. The software is based on the supplier-independent FDT/DTM technology.
The ACT20C has been designed specifically for process automation in order to continuously forward measured values and status information to networked devices. During standard operation, malfunction, maintenance or configuration via the network, this allows a precise display of the current status. In case of error, the ACT20C supplies precise information for error analysis and can therefore contribute to higher system availability.
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Brochures
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-90
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
Approvals
DNVGL;
ROHS
Conform
Colour:
black
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
Order No.:
2044840000
Type of connection:
Screw connection
Type:
ACT20C-CML-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510240000
Type of connection:
Screw connection
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510420000
Type of connection:
Screw connection
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510370000
Type of connection:
RJ45 plug-in connector
Type:
ACT20C-GTW-100-MTCP-S
Version:
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus
Order No.:
1510340000
Type of connection:
socket / socket
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
Order No.
1334490000
Type
ACT20C-AI-AO-MTCP
GTIN (EAN)
4050118137675
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2023-05-31
Depth
113.6 mm
Depth (inches)
4.472 inch
Width
22.5 mm
Width (inches)
0.886 inch
Length
119.2 mm
Length (inches)
4.693 inch
Net weight
169 g
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...70 °C
Humidity
0...95 % (no condensation)
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input current
0...20 mA, 4...20 mA
Input voltage
0(2)…10 V
Number of inputs
1
Sensor supply
> 17 V DC at 20 mA
Addressing
DHCP or manual adjustment
Interface
RJ45: female-female, Cat.5 to 100 MHz, Jack plug for CBX200
Protocol
FDT/DTM, Modbus/TCP
Load impedance current
≤ 500 Ω
Number of outputs
1
Output current
0...20 mA, 4...20 mA
Output voltage, note
0...10 V
load impedance voltage
≥ 10 kΩ
Load resistance current
≤ 500 Ω
Load resistance voltage
≥ 10 kΩ
Output current
0(4)...20 mA
Output voltage
0...10 V
Transmit function
direct or inverted
Accuracy
< 0.15% end value (+ 0.05% > 55 °C), Current: 1 uA / 30 uA (+ 10 uA > 55°C), Voltage: 1 mV / 15 mV (+ 5 mV > 55°C)
Configuration
FDT/DTM (Ethernet or service interface)
Galvanic isolation
4-way isolator;, between input / output / power supply / Ethernet
Power consumption
≤ 3.5 W
Protection degree
IP20
Rail
TS 35
Temperature coefficient
≤ 0.01 % / °C
Voltage supply
24 V DC ± 25 %
EMC standards
EN 61326-1:2006
Galvanic isolation
4-way isolator;, between input / output / power supply / Ethernet
Pollution severity
2
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional earth to supply ⁄ Ethernet interface
31.2 V DC / 0.9 kV rms in secondary electrical circuits, basic insulation
Rated voltage ⁄ test voltage: functional earth to input ⁄ output
300 Vrms / 1.1 kV rms in secondary electrical circuits, basic insulation
Rated voltage ⁄ test voltage: input/output to output/input ⁄ supply⁄ Ethernet interface
300 Vrms / 1.7 kV rms in secondary electrical circuits, reinforced insulation
Recommendations
Namur NE43, Namur NE44, Namur NE107
Type of connection
Screw connection/ RJ45 plug-in connector
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Product information
With the ACT20C, Weidmüller is presenting a completely new type of signal converter. The compact module is equipped with an Ethernet connection and provides, in addition to signals, precise information on the status of sensors, signal processing and cabling.
ACT20C, as a signal converter, isolates, scales and converts analogue current and voltage signals; it can be configured directly with the "WI-Manager" software or via an Ethernet network. The software is based on the supplier-independent FDT/DTM technology.
The ACT20C has been designed specifically for process automation in order to continuously forward measured values and status information to networked devices. During standard operation, malfunction, maintenance or configuration via the network, this allows a precise display of the current status. In case of error, the ACT20C supplies precise information for error analysis and can therefore contribute to higher system availability.
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Brochures
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-90
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
DNVGL;
ROHS
Conform
Colour:
black
Order No.:
1335140000
Type:
SET CH20M BUS 250MM TS 35X7.5
Version:
OMNIMATE Housing - series CH20M, Length: 250 mm, Width: 25.1 mm
Order No.:
2044840000
Type of connection:
Screw connection
Type:
ACT20C-CML-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510240000
Type of connection:
Screw connection
Type:
ACT20C-CMT-10-AO-RC-S
Version:
Current-measuring transducer, Input : 0…5/10 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510420000
Type of connection:
Screw connection
Type:
ACT20C-CMT-60-AO-RC-S
Version:
Current-measuring transducer, Input : 0…40/50/60 A, Output : 0(4)-20 mA, 0-10 V, Relay
Order No.:
1510370000
Type of connection:
RJ45 plug-in connector
Type:
ACT20C-GTW-100-MTCP-S
Version:
Gateway for ACT20C station, Configurable, Modbus TCP/IP, Distributes supply voltage to rail bus
Order No.:
1510340000
Type of connection:
socket / socket
Type:
ACT20C-LBT-10
Version:
Bus termination terminal for ACT20C station, Input : 0…40/50/60 A, Output : Pulse
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.