Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
Cord sets, Patchcords and Cables
PLC Interfaces and Migration Solutions
Service Interfaces
Distribution Boxes
RJ45 & Circular Connectors patchcable & cord sets
RJ12 patch cable
Single Pair Ethernet cord sets
Fibre-optic cabling solutions
Cable Assemblies
Valve plug with integrated seal
PushPull Power cord sets
USB cord sets
Raw cable
Cables with customer-specific assembly
Copper
Railway cable, Radox, black
MCSMCA
General ordering data
Version
System cable, M12 D-code – IP 67 straight pin, M12 D-code – IP 67 angled pin, Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B), Radox GKW S, 0.3 m
Order No.
1059940003
Type
IE-C5DB4RE0003MCSMCA-E
GTIN (EAN)
4050118112443
Qty.
1 pc(s).
Delivery status
Discontinued
Available until
2014-05-20
Dimensions and weights
Length
0.3 m
Length (inches)
11.811 inch
Net weight
62 g
Temperatures
Storage temperature
-40 °C...90 °C
Operating temperature
-40 °C...90
Installation temperature
-25 °C...90 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
RoHS Compliance Status
Compliant
Cable specific standards
Corrosiveness of fumes
to IEC 60754-2
Fire protection in buses
According to ISO 6722-1 5.22 (UN ECE-R 118.01)
Fire safety for railway vehicles
According to DIN 5510-2 fire safety levels 1,2,3,4, According to BS 6853, According to EN50288-2-2, According to EN 45545, HL1 - HL3
Flames propagate vertically on bundled cables
According to BS4066-3, DIN EN 50266-2-5, According to IEC 60332-3-25 D
Fluorine content
According to EN 60684-2 Section 45.2
Hydrogen halide content
According to EN-50267-2-1, According to IEC 60754-1
Impervious to smoke
According to BS 6853 Appendix D, in accordance with EN 50268-2, According to IEC 61034-2
Multi-wire metallic data and control cable
According to EN50288-2-2
Poisonous gases
According to BS 6853 Appendix B
Cable structure
Cross-section
2*2*AWG 22/7 - 2*2*0.36 mm²
Insulation cross-section
1.95 mm
Material sheath
Radox GKW S
Sheath diameter, max.
7.55 mm
Sheath diameter, min.
6.95 mm
Sheathing colour
black
Shielding
SF/UTP
Strands
7
Electrical properties of cable
Category
Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B)
Mechanical and material properties of cable
Abrasion resistance
very good
Corrosiveness of fumes
to IEC 60754-2
Halogen
halogen-free, according to IEC 60754-2
Impervious to smoke
According to BS 6853 Appendix D, in accordance with EN 50268-2, According to IEC 61034-2
Min. bending radius, repetitive
6 *diameter
Resistance to oils
in accordance with EN 50306-3
Plug
Plug left
M12, D-coded, IP67, male contact, straight, Zinc diecast, shielded
Plug right
M12, D-coded, IP67, male contact, angled 90°, Zinc diecast, shielded
Plug, left
Plug left
M12, D-coded, IP67, male contact, straight, Zinc diecast, shielded
Plug, right
Plug right
M12, D-coded, IP67, male contact, angled 90°, Zinc diecast, shielded
There are no products in this group.
Version
System cable, M12 D-code – IP 67 straight pin, M12 D-code – IP 67 angled pin, Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B), Radox GKW S, 0.3 m
Order No.
1059940003
Type
IE-C5DB4RE0003MCSMCA-E
GTIN (EAN)
4050118112443
Qty.
1 pc(s).
Delivery status
Discontinued
Available until
2014-05-20
Length
0.3 m
Length (inches)
11.811 inch
Net weight
62 g
Storage temperature
-40 °C...90 °C
Operating temperature
-40 °C...90
Installation temperature
-25 °C...90 °C
REACH SVHC
Lead 7439-92-1
RoHS Compliance Status
Compliant
Corrosiveness of fumes
to IEC 60754-2
Fire protection in buses
According to ISO 6722-1 5.22 (UN ECE-R 118.01)
Fire safety for railway vehicles
According to DIN 5510-2 fire safety levels 1,2,3,4, According to BS 6853, According to EN50288-2-2, According to EN 45545, HL1 - HL3
Flames propagate vertically on bundled cables
According to BS4066-3, DIN EN 50266-2-5, According to IEC 60332-3-25 D
Fluorine content
According to EN 60684-2 Section 45.2
Hydrogen halide content
According to EN-50267-2-1, According to IEC 60754-1
Impervious to smoke
According to BS 6853 Appendix D, in accordance with EN 50268-2, According to IEC 61034-2
Multi-wire metallic data and control cable
According to EN50288-2-2
Poisonous gases
According to BS 6853 Appendix B
Cross-section
2*2*AWG 22/7 - 2*2*0.36 mm²
Insulation cross-section
1.95 mm
Material sheath
Radox GKW S
Sheath diameter, max.
7.55 mm
Sheath diameter, min.
6.95 mm
Sheathing colour
black
Shielding
SF/UTP
Strands
7
Category
Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B)
Abrasion resistance
very good
Corrosiveness of fumes
to IEC 60754-2
Halogen
halogen-free, according to IEC 60754-2
Impervious to smoke
According to BS 6853 Appendix D, in accordance with EN 50268-2, According to IEC 61034-2
Min. bending radius, repetitive
6 *diameter
Resistance to oils
in accordance with EN 50306-3
Plug left
M12, D-coded, IP67, male contact, straight, Zinc diecast, shielded
Plug right
M12, D-coded, IP67, male contact, angled 90°, Zinc diecast, shielded
Plug left
M12, D-coded, IP67, male contact, straight, Zinc diecast, shielded
Plug right
M12, D-coded, IP67, male contact, angled 90°, Zinc diecast, shielded
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.